TROUBLESHOOTING
Self-Diagnostic Codes
SET TEMP
FAN ON/OFF
COOL ON/OFF
Classic Plus
Code | Condition |
dF | When the evaporator thermistor |
| disengages the compressor. |
FL | When the drain tank switch shuts |
| off the unit (FULL TANK LED |
| flashes). |
AS | When unit disengages the com- |
| pressor while the condensate |
| pump is discharging water. |
HP | When the high pressure switch |
| disengages the compressor. |
Check the following points before calling a qualified technician.
SYMPTOM | POSSIBLE CAUSE | REMEDY |
|
|
|
Unit does not operate | ➀Ground fault breaker blown | Reset breaker |
| ➁Drain tank is full | Empty the drain tank |
| (FULL TANK LED will be |
|
| flashing) |
|
Insufficient cooling | ➀Dirty/blocked air filters | Clean air filters |
| ➁Air inlet/outlet blocked | Clear air inlet/outlet |
| ➂Improper temperature setting | Set to desired position |
|
|
|
If symptoms persist after the above actions have been taken, turn the unit off, disconnect the power cord plug and contact your MovinCool reseller.
17