![INSTALLATION INSTRUCTIONS](/images/new-backgrounds/43882/438825x1.webp)
INSTALLATION INSTRUCTIONS
GAS CONTROL VALVE CONVERSION
Convert the gas control valve by swapping out the valve regulator portion of the gas valve.
1.Using a TORX T20 or slotted screw- driver, remove and discard the three mounting screws, pressure regulator tower, and diaphragm/spring compo- nents (see Figure 6).
2.Insure that the rubber gasket is prop- erly positioned on the new pressure regulator assembly. Install the new pressure regulator assembly to the valve using the new mounting screws sup- plied with the kit. Tighten screws se- curely (approximately
3.Install the identification label enclosed with the gas valve regulator to the valve body where it can easily be seen (see Figure 7).
CONVERSION LABELING AND PLACEMENT
1.Apply the English and French conver- sion labels over the top of the existing certification labels (see Figure 8). Ex- isting certification labels are located on the lighting instruction plate inside the gas valve compartment area. With per- manent ink, print the previous model number on the label in the space pro- vided (see Figure 9).
2.After filling in the data required on the conversion information label, affix it to the floor of the appliance where it is easily seen when the bottom louver panel is opened (see Figure 10).
LO
HI
Mounting Screws
French This
English This Side
Side
Lighting Instruction
Plate
Figure 8 - Applying English and French Conversion Labels over Existing Certification Labels on Lighting Instruction Plate
DIRECT VENT DECORATIVE FIREPLACE
Conversion Kit Model
Type of Gas
Mounting
Screws
Pressure
Regulator
Tower
Diaphragm/
Spring
Components
LO
HI
OFF
NO TOLPI
Rubber Gasket
Identification Label
Figure 7 - Installing Pressure Regulator Assembly
®
Previous Model #
Figure 9 - Print Previous Model Number on Conversion Labels
CONVERSION INFORMATION LABEL
This appliance was converted on
| O |
| FF |
N | P |
LI | |
O TO |
– |
| – |
| to |
| gas |
Day Month Year
with Kit No.
by
(name and address of organization making this conversion), which accepts the responsibility that this conversion has been properly made.
56060 |
Figure 10 - Conversion Information Label
Figure 6 - Removing Mounting Screws,
Pressure Regulator Tower, and
Diaphragm/Spring Components
105822 | 3 |