Desa 10BY150ECB Troubleshooting, MODEL BY150ECB 150,000 Btu/Hr, Portable Forced Air Heater

Models: 10BY150ECB

1 16
Download 16 pages 51.16 Kb
Page 6
Image 6
TROUBLESHOOTING

MODEL BY150ECB 150,000 Btu/Hr

PORTABLE FORCED AIR HEATER

TROUBLESHOOTING

See Pump Pressure Adjustment, page 7. WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts Wrong pump pressure off heater after a short period of time.

See Pump Pressure Adjustment, page 7.

 

Dirty air output, air intake and/or

See Air Output, Air Intake and Lint Filters,

 

lint filters

page 7.

 

Dirty fuel filter

See Fuel Filter, page 8.

 

Dirt in nozzle

See Nozzle, page 8.

 

Dirty photocell lens

Clean photocell lens.

 

Bad flame-out control

Replace flame-out control.

 

 

 

Heater will not ignite, but motor runs for a

Wrong pump pressure

See Pump Pressure Adjustment, page 7.

short period of time.

 

 

Carbon deposits on spark plug and/or improper gap

Dirty fuel filter

Dirt in nozzle

Water in fuel tank

See Fuel Filter, page 8. WARNING: High voltage!

Electronic ignitor not grounded

Bad electronic ignitor

See Spark Plug, page 8.

See Fuel Filter, page 8.

See Nozzle, page 8.

Drain and flush fuel tank with clean kerosene. See Storing, Transporting, or Shipping, page 5.

Make sure electronic ignitor mounting is tight.

Replace electronic ignitor.

Motor does not start when heater is plugged ON/OFF switch not on

Press ON/OFF switch to on

in, fan rotates slowly or does not turn.

 

Flame-out control not reset

Solid state relay not allowed to reset

Binding pump rotor

Press flame-out control reset button.

Wait two minutes before trying to restart heater.

If fan is hard to turn, see Pump Rotor, page 9.