TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
OBSERVED FAULT | POSSIBLE CAUSE | REMEDY |
Heater ignites, but
See Pump Pressure Adjustment, page 7.
| Dirty air output, air intake and/or | See Air Output, Air Intake and Lint Filters, |
| lint filters | page 7. |
| Dirty fuel filter | See Fuel Filter, page 8. |
| Dirt in nozzle | See Nozzle, page 8. |
| Dirty photocell lens | Clean photocell lens. |
| Bad | Replace |
|
|
|
Heater will not ignite, but motor runs for a | Wrong pump pressure | See Pump Pressure Adjustment, page 7. |
short period of time. |
|
|
Carbon deposits on spark plug and/or improper gap
Dirty fuel filter
Dirt in nozzle
Water in fuel tank
WARNING: High voltage!
Electronic ignitor not grounded
Bad electronic ignitor
See Spark Plug, page 8.
See Fuel Filter, page 8.
See Nozzle, page 8.
Drain and flush fuel tank with clean kerosene. See Storing, Transporting, or Shipping, page 5.
Make sure electronic ignitor mounting is tight.
Replace electronic ignitor.
Motor does not start when heater is plugged ON/OFF switch not on | Press ON/OFF switch to on |
in, fan rotates slowly or does not turn. |
|
Solid state relay not allowed to reset
Binding pump rotor
Press
Wait two minutes before trying to restart heater.
If fan is hard to turn, see Pump Rotor, page 9.
6 | 104001 |