Desa 5511 manual Compact 150 Watt Motion Sensing Halogen, Operation, Model, On-Time, Test, Auto

Models: 5511

1 8
Download 8 pages 58.29 Kb
Page 1
Image 1
Compact 150 Watt Motion Sensing Halogen

®

Compact 150 Watt Motion Sensing Halogen

Model 5511

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

 

x

Manual

Until Dawn*

 

x

* resets to Auto Mode at dawn.

Note: When fi rst turned on wait about 11/2 minutes for the circuitry to calibrate.

The Motion Sensor Quartz Security Light turns on 150 watts of quartz-halogen lighting when motion is detected and then, after a selectable period of time, automati- cally turns the lighting off. The built-in photocell keeps the lighting off during daylight hours.

TEST

Put the ON-TIME switch on the bottom of the sensor in the TEST position.

AUTO

ON-TIME

10 5 1 TEST

This package includes:

Cover Plate

Cover Plate

Gasket

ON-TIME

Put the ON-TIME switch in the 1, 5, or 10 minute position.

10 5 1 TEST

MANUAL MODE

 

 

4 Screws

 

 

(2 sizes)

Sensor

 

Halogen

 

Bulb

 

 

 

Light Fixture

3 Wire

 

 

 

 

Connectors

Requirements

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

The Light Control requires 120-volts AC. Do not con- nect through a dimmer or other electronic switch.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at Home Centers and Electrical Supply Stores.

© 2007 DESA Specialty Products™

Mode Switching Summary

 

TEST

 

 

Move ON-TIME Switch

 

 

 

 

 

 

 

 

 

 

 

to 1, 5, or 10 minutes

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

Flip switch off for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

one second then

 

 

 

 

 

 

 

back on*
MANUAL MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time (11/2 min.) the control will be in the AUTO mode.

598-1310-00

Page 1
Image 1
Desa 5511 manual Compact 150 Watt Motion Sensing Halogen, Operation, Model, On-Time, Test, Auto, one second then, back on