TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When fi rst turned on, wait about 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

 

 

 

 

 

 

 

SENS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN MAX

10 5 1 TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor to aim.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.Keep the sensor at least 1" (25 mm) away from the lamps.

Set SENSITIVITY as needed. Too much sensitivity may increase false triggering.

Secure the sensor head into position by tightening the clamp screw. Do not over- tighten the screw.

Clamp

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects refl ecting light may trigger the shut-off feature. Do not point other lights at the sensor.

110°

8ft.

(2.4 m)

60 ft.

(18.3 m)

Maximum Range
Maximum

 

Coverage Angle

The control is most sensitive to motion across it.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

Set the amount of TIME the lights stay on after motion is

detected. It is selectable from 1, 5, or 10 minutes.

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 60 ft.(18.3 m);[varies with surrounding temperature]

Sensing Angle . . . . . . . Up to 110°

Electrical Load. . . . . . . Up to 150 Watts Maximum tungsten

Power Requirements . . 120 VAC, 60 Hz

Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5, or 10 minutes Sensitivity . . . . . . . . . . Adjustable

Replacement lamp. . . . T 150W (or less) halogen 120

VAC