Desa 5512 manual Operation, Model, Features, Mode Switching Summary, Requirements, Level, On-Time

Models: 5512

1 8
Download 8 pages 23.13 Kb
Page 1
Image 1
Model 5512

®

Twin Halogen Motion Sensing Light with 2-Level Lighting

Model 5512

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

2-Level Lighting Timer.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Sec

x

x

Auto

1, 5, 20 min.

 

x

Manual

Until Dawn*

 

x

 

 

 

 

* resets to Auto Mode at dawn.

Note: When fi rst turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put ON-TIME switch ON-TIME

 

2-Level

on the sensor bot-

 

 

 

 

 

Lighting

 

 

 

 

tom to TEST and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

 

 

 

 

 

the 2-Level Lighting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off 3 6 Dusk to

switch OFF.

 

 

 

 

 

 

 

 

 

 

 

Dawn

 

 

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5,

 

 

ON-TIME

or 20 minute position.FeaturesOPERATION TEST 1 5 20

MANUAL MODE

Plastic Hanger

Rubber Plug

6 Mounting

Cover Screws (3 sizes) Test Plate

3 Wire

Connectors

AutoManual Sensor

Light Control

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.

1 Second OFF

then...

... back on.

Mounting Bolt

Mounting Strap

 

Gasket

Mode Switching Summary

TEST

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

1, 5, or 20 minutes

 

 

 

 

2 Halogen Bulbs

Light Shield

Requirements

The Light Control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

© 2007 DESA Specialty Products™

AUTOFlip light switch

off for one second

then back on*

MANUAL MODE

*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.

2-LEVEL LIGHTING TIMER

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.

598-1275-00

Page 1
Image 1
Desa 5512 manual Operation, Model, Features, Mode Switching Summary, Requirements, Levellighting Timer, Lighting, On-Time