Desa 5512 CAUTION To Avoid Fire Or Burn Hazards, Bulb Installation, Wire The Light Control

Models: 5512

1 8
Download 8 pages 23.13 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.

CAUTION: Keep the sensor at least 1" (2.5 cm) away from the lamps.

CAUTION: To Avoid Fire Or Burn Hazards:

Allow fi xture to cool before touching. The bulb and the fi xture operate at high temperatures.

Keep fi xture at least 2" (5 cm) from combustible materi- als. Do not aim at objects closer than 3 feet. (1 m).

Use only T3, 150W (max.) tungsten halogen 120 VAC lamps.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing from the Light Shield and stick on as shown below.

For eave mount only:

Swing the sensor head towards the clamp screw joint.

Controls

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Light Shield

Opening

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

BULB INSTALLATION

NOTE: Lamps are included, but you will need to install them

NOTE: When re-lamping, turn power off and let the fi xture cool.

Open glass covers.To remove the old bulb push the bulb towards the right (with fi xture as shown) until the left side of the bulb is clear of the left socket.

To install a bulb, push the bulb into the right socket so the bulb fi ts completely into the left socket.

Check that the bulb is seated properly.

Close the glass covers.

WIRE THE LIGHT CONTROL

CAUTION: To Avoid Fire Or Burn Hazards: WARNING: Turn power off at circuit breaker.

Remove the existing light fi xture.

Install mounting strap to junction box using screws appropriate for your junction box.

The plastic hanger can be used to hold the fi xture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Thread all fi xture wires through the large holes in the gasket as shown.

Connect the junction box wires to the light fi xture wires as shown. Twist together and secure with wire connectors.

White to White

Black to Black

Gasket

Rubber Plug

Mounting

Bolt

Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.

MOUNT THE LIGHT CONTROL

Place the Mounting Bolt through the front of the junction box cover. Push the small gasket hole over the Mounting Screw.

Make sure the wire connectors and wires are inside the junction box. Align the Mounting Screw with the center hole in the Mounting Strap.Secure the fixture to the Mounting Strap.

Push the Rubber Plug over the mounting screw.

Keep lamps at least 1" (2.5 cm) from the sensor.

Push the Rubber Plug fi rmly into place.

If not installed on a weatherproof box, caulk the wall plate and mounting surface with silicone

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting.

2

598-1275-00

Page 2
Image 2
Desa 5512 CAUTION To Avoid Fire Or Burn Hazards, Bulb Installation, Wire The Light Control, Mount The Light Control