Desa 6000 BTU/HR Lighting Instructions, To Turn Off Gas To Appliance, Manual Lighting Procedure

Models: 6000 BTU/HR

1 20
Download 20 pages 61.9 Kb
Page 10
Image 10
LIGHTING

BLUE FLAME 6000 BTU/HR

VENT FREE PROPANE/LP GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, page 9, column 3.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseTO TURN OFF GAS to the OFF position.

Ignitor Button

Control Knob

Note: If pilot does not stay lit, refer to Troubleshooting, pages 12 through

14.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

Ignitor Pilot

Thermocouple Electrode Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise ClockwiseShutting Off Heater to the PILOT position.

2.Press in control knob and turn clock-

wise ClockwiseShutting Off Burner Only (pilot stays lit) to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise ClockwiseMANUAL LIGHTING to the PILOT position.

MANUAL LIGHTING

PROCEDURE

PILOT OFF

HIGH

IGNITOR

LOW

Figure 16 - Control Knob In The OFF Position

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation at the top of page 16. If you don’t smell gas, go to the next step.

5.Press in control knob and turn coun- terclockwise Manual backgroundC-clockwiseto the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 16, page 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Figure 17 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise

Manual backgroundC-clockwiseto the HIGH position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from HIGH to a lower setting, press in the control knob and turn counterclock-

wise Manual backgroundC-clockwise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

Manual background CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after pilot is lit. After 30 sec- onds, release control knob.

5.Replace front panel.

10

103112

Page 10
Image 10
Desa 6000 BTU/HR Lighting Instructions, To Turn Off Gas To Appliance, Manual Lighting Procedure, Shutting Off Heater