THEORY OF OPERATION

THEORY OF OPERATION

The Fuel System: The hose/regulator assembly attaches to the propane gas supply. The propane gas moves through the automatic control valve and out the nozzle.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

Combustion Chamber

Clean Heated Air Out (Front)

The Ignition System: The spark transformer and spark plug lights the main burner

The Safety Control System: This system causes the heater to shut down if the flame goes out.

Note: Some parts are located differently on some models.

Nozzle

Fan

Motor

Cool

Air In (Back)

Power Cord

Air For Combustion

Fuel

Hose/Regulator

Assembly

And Heating

 

 

Figure 2 - Cross Section Operational View (Heater may vary from illustration)

PROPANE SUPPLY

Propane gas and propane tank(s) are to be fur- nished by the user.

Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58. Your local library or fire department will have this booklet.

The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount:

1.The amount of propane gas in tank(s)

2.The temperature of tank(s)

The chart below shows the number of 100 pound

(45 kg) tanks needed to run this heater.

 

Number of tanks

Temperature

 

Models

at tank location

55

85

125

above 20° F (-7° C)

1

1

2

20° F (-7° C) to -0 (-18° C)

1

2

3

below -0° F (-18° C)

2

2

(Use larger

 

 

 

tank)

Less gas is vaporized at lower temperatures. You may need two or more 100 pound (45 kg) tanks or one larger tank in colder weather. Your local propane gas dealer will help you select the proper supply system. The minimum surrounding-air tem- perature rating for each heater is -20° F (-29° C).

INSTALLATION

PROPANE SUPPLY WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

INSTALLATION WARNING:Testallgaspiping and connections for leaks after installing or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.