Desa Air Conditioner Troubleshooting, WARNING Useonlyinareas free of high dust content, Remedy

Models: Air Conditioner

1 18
Download 18 pages 50.43 Kb
Page 7
Image 7
TROUBLESHOOTING

TROUBLESHOOTING

OBSERVED PROBLEM WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

Fan does not turn when heater

1. No electrical power to heater

1.

Check voltage to electrical

is plugged in

 

 

outlet. If voltage is good,

 

 

 

check heater power cord for

 

2. Fan hitting inside of heater

 

breaks

 

2.

Adjust motor/fan mount to

 

shell

 

keep fan from hitting inside of

 

 

 

heater shell. Bend fan mount

 

 

 

if necessary

 

3. Fan blades bent

3.

Replace fan. See Fan, page 8

 

4. Defective motor

4.

Replace motor. See Motor,

 

 

 

page 8

 

 

 

 

Heater will not ignite

1. User did not follow installa-

1.

Repeat installation and opera-

 

tion or operation instructions

 

tion instructions. See Instal-

 

properly

 

lation, page 4 and Operation,

 

2. No spark at spark plug. To test

 

page 5

 

2.

A) Check spark plug wire.

 

for spark, follow step 8 under

 

Tighten or reattach loose spark

 

Spark Plug, page 9. If you see

 

plug wire. See Figure 8, page 9

 

spark at spark plug, have heater

 

for spark plug wire location

 

serviced by qualified service

 

B) Replace spark plug. See

 

person. If no spark seen:

 

Spark Plug, page 9

 

A) Loose or disconnected

 

C) Replace spark transformer.

 

spark plug wire

 

See Spark Transformer, page 9

 

B) Bad spark plug

 

 

 

C) Bad spark transformer

 

 

Heater shuts down while run- ning

1.Propane supply may be inad- equate

2.High surrounding air tem- perature causing thermal limit device to shut down heater.

3.Restricted air flow

4.Damaged fan

5.Excessive dust or debris in surrounding area

1.A) Refill tank

B)Provide additional and/or larger tanks. See Propane Supply, page 4

2.This can happen when running heater in temperatures above 85° F (29° C). Run heater in cooler temperatures

3.Check heater inlet and outlet. Remove any obstructions

4.Replace fan. See Fan, page 8

5.Clean heater. See Mainte- nance, page 6

POSSIBLE CAUSE WARNING:Useonlyinareas free of high dust content.

113893-01B

www.desatech.com

7

Page 7
Image 7