20

INSTALLATION

Checking Gas Connections (Cont.)

Optional Wireless Hand-Held Remote Control Accessories [Remote-Ready Models Only]

INSTALLATION

Continued

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figures 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

OPTIONAL WIRELESS HAND-HELD REMOTE

CONTROL ACCESSORIES

Remote-Ready Models Only

(GHRCB Series & GHRCTB Series)

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33, page 19).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas regulator (Thermostat-Controlled Models), or to gas control valve (Remote- Ready Models) (see Figures 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fireplace, pages 23 through 27). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 24 for Thermostat-Controlled Models or page 25 for Remote- Ready Models).

Equipment

Gas Regulator or

Gas Control Valve

Shutoff Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Propane/LP

Supply

Tank

Figure 34 - Checking Gas Joints (Propane/LP Only)

Gas Regulator or

Gas Control Valve

Equipment

Shutoff Valve

Gas Meter

Figure 35 - Checking Gas Joints (Natural Gas Only)

Installing Receiver

1.Remove screws.

2.Disconnect switch wires from the control valve.

3.Remove switch plate (see Figure 36). Discard switch plate after removing. Save the screws.

4.Locate the battery clip mounted on the back of the receiver (see Figure 37).

5.Slide 9-volt battery (not included) through the clip.

6.Attach the terminal wires to the battery (see Figure 37).

7.Connect wires as shown in Figure 38, page 21.

8.Install remote receiver unit onto fireplace base using the two screws removed in step one (see Figure 38, page 21).

Switch Plate

Screw

Red Wire

Black

Wire

Figure 36 - Switch Plate and Wiring Harness

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 37 - Attaching Battery to Receiver

For..com

107032-01H

Page 20
Image 20
Desa and EFS26NR Optional Wireless HAND-HELD Remote Control Accessories, Pressure Testing Fireplace Gas Connections

EFS10TP, EFS10TN, and EFS26NR specifications

Desa is a recognized leader in the innovation and manufacture of advanced heating solutions designed to deliver optimal performance and efficiency. Among their most notable offerings are the EFS26NR, EFS10TP, and EFS10TN models, each engineered with unique features and technologies to meet diverse heating needs.

The EFS26NR is a notable model known for its large heating capacity and effectiveness in maintaining consistent warmth in larger spaces. With a robust output, this unit can efficiently heat areas up to 1,800 square feet, making it suitable for homes or commercial settings. One of the primary characteristics of the EFS26NR is its advanced heating technology, which includes a high-efficiency burner that maximizes fuel usage, reducing operational costs. Additionally, it features a built-in thermostat, providing automated temperature adjustments for enhanced comfort.

On the other hand, the EFS10TP is designed for versatility and practicality. This model is ideal for smaller rooms or as a supplementary heating option. The EFS10TP offers users the convenience of a portable heater equipped with wheels, allowing for easy mobility. This model is equipped with user-friendly controls and a safety shut-off feature, ensuring peace of mind while in use. The EFS10TP utilizes a compact design without sacrificing performance, allowing it to fit seamlessly into various settings.

Similar in size, the EFS10TN focuses on energy efficiency as its main selling point. This model uses a unique infrared heating technology that allows for more direct heating of objects and people rather than warming the air, resulting in lower energy consumption. The EFS10TN is perfect for those looking to reduce their carbon footprint while still achieving a warm, inviting environment. Enhanced safety features such as tip-over protection and overheat shut-off further ensure its suitability for use in homes with children or pets.

Overall, the Desa heating solutions—EFS26NR, EFS10TP, and EFS10TN—each provide distinct advantages tailored to specific heating requirements. With a commitment to innovation, safety, and efficiency, these models are exemplary choices for those seeking dependable and effective heating options. Whether for large areas or cozy spaces, Desa ensures that there is a suitable solution for every heating need.