INSTALLATION

Installing Blower Accessory GA3450T in Remote-Ready Models (Cont.)

13

INSTALLATION

Continued

Installing Blower Accessory

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

CAUTION: Verify proper operation after servicing.

Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation, page 14.

1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.

2.Make sure the wire harness is firmly connected to the termi- nals on the blower bracket assembly.

3.Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 16).

4.Carefully disconnect green and white wires at their insulated connectors (see Figure 17).

Blower Bracket

Wire

Wiring Routing

Harness

Hole in Baffle

Assembly

5.In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 16).

6.Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening on the side of the valve cover shield. (see Figure 16).

7.Insert the 4 wire harnesses into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see Figure 16).

8.Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.

9.Install the switch plate on the valve cover shield with 2 #10 screws provided (see Figure 18). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 16). Plug fan kit into 120-Volt grounded power supply and test operation. Note: When switch is in the AUTO position, the fan will start after the fireplace has run for a few moments. The fan will continue to run for several moments after the fireplace has been turned off. When switch is in the ON position, the fan will run until turned to OFF. Reinstall upper louver assembly (see Fig- ure 15, page 12) and branch support. Close lower louver door.

Fan Switch

(Auto/Off/On)

1Auto

Screw

Baffle

Blower

 

 

Mounting

Holes

 

 

Off

2

 

 

 

3

 

 

 

On

110/115

Red

 

V.A.C.

 

 

 

Black

 

 

 

 

 

 

White

 

 

 

Green

 

Blue Thermostat

Switch

(N.O.)

Blue

Blower

Motor

Red

White

Green

Switch

Power Cord

Snap

 

 

 

Bushing

3

 

 

2

 

 

1

 

 

Switch

Plate Blue

Black Red

Wire Harness

Valve Cover Shield

Lower Louver Door

Figure 16 - Installing Blower Bracket Assembly

Figure 17 - Wiring Diagram For Blower Accessory Standard Installation

Valve Cover

Shield

Switch

Plate

Screw

Figure 18 - Installing Switch Plate to Valve Cover Shield

For morevisit www..com

107032-01H

Page 13
Image 13
Desa EFS10TP, EFS10TN, and EFS26NR installation manual Installing Blower Accessory, Power Cord Snap

EFS10TP, EFS10TN, and EFS26NR specifications

Desa is a recognized leader in the innovation and manufacture of advanced heating solutions designed to deliver optimal performance and efficiency. Among their most notable offerings are the EFS26NR, EFS10TP, and EFS10TN models, each engineered with unique features and technologies to meet diverse heating needs.

The EFS26NR is a notable model known for its large heating capacity and effectiveness in maintaining consistent warmth in larger spaces. With a robust output, this unit can efficiently heat areas up to 1,800 square feet, making it suitable for homes or commercial settings. One of the primary characteristics of the EFS26NR is its advanced heating technology, which includes a high-efficiency burner that maximizes fuel usage, reducing operational costs. Additionally, it features a built-in thermostat, providing automated temperature adjustments for enhanced comfort.

On the other hand, the EFS10TP is designed for versatility and practicality. This model is ideal for smaller rooms or as a supplementary heating option. The EFS10TP offers users the convenience of a portable heater equipped with wheels, allowing for easy mobility. This model is equipped with user-friendly controls and a safety shut-off feature, ensuring peace of mind while in use. The EFS10TP utilizes a compact design without sacrificing performance, allowing it to fit seamlessly into various settings.

Similar in size, the EFS10TN focuses on energy efficiency as its main selling point. This model uses a unique infrared heating technology that allows for more direct heating of objects and people rather than warming the air, resulting in lower energy consumption. The EFS10TN is perfect for those looking to reduce their carbon footprint while still achieving a warm, inviting environment. Enhanced safety features such as tip-over protection and overheat shut-off further ensure its suitability for use in homes with children or pets.

Overall, the Desa heating solutions—EFS26NR, EFS10TP, and EFS10TN—each provide distinct advantages tailored to specific heating requirements. With a commitment to innovation, safety, and efficiency, these models are exemplary choices for those seeking dependable and effective heating options. Whether for large areas or cozy spaces, Desa ensures that there is a suitable solution for every heating need.