OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue for damage. If damaged, operate heater with flue damper closed.

WARNING: Seal any fresh air vents or ash clean-out doors lo- cated on floor or wall of fireplace.

WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance (see page 10)

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND

CLEARANCES (Vent-Free

Operation Only)

WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

 

 

 

18", 24",

16"

42"

and 30"

 

 

LOG SIZING REQUIREMENTS

Log

Minimum Firebox Size

Size

Height

Depth

Front

Rear*

 

 

 

Width

Width

18"

17"

14"

24"

20"

24"

17"

14"

28"

21"

30"

17"

14"

34"

24"

 

 

 

 

 

*Measured at 14" depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, factory built UL 127-listed manufactured fireplace, or listed vent free firebox.

Minimum Wall and Ceiling Clearances (see Figure 4)

A.Clearances from the side of the fire- place opening to any combustible wall should not be less than 16 inches.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

42"

Left and

Right

Sides

16"

Figure 4 - Minimum Clearance to Wall and Ceiling