FIREPLACE MANUFACTURERS INCORPORATED
UNVENTED NATURAL GAS LOG HEATER
TROUBLESHOOTING
Continued
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
Burner does not light after ODS/pilot is lit | 1. | Inlet gas pressure is too low | 1. | Contact local natural gas company |
| 2. | Burner orifice clogged | 2. | Clean burner (see Cleaning and Mainte- |
|
|
|
| nance, page 20) or replace burner orifice |
| 3. | Burner orifice diameter is too small | 3. | Replace burner orifice |
|
|
|
|
|
Delayed ignition burner | 1. | Manifold pressure is too low | 1. | Contact local natural gas company |
| 2. | Burner orifice clogged | 2. | Clean burner (see Cleaning and Mainte- |
|
|
|
| nance, page 20) or replace burner orifice |
|
|
|
|
|
Burner backfiring during combustion | 1. | Burner orifice is clogged or damaged | 1. | Clean burner (see Cleaning and Mainte- |
|
|
|
| nance, page 20) or replace burner orifice |
| 2. | Damaged burner | 2. | Replace damaged burner |
| 3. | Gas regulator defective | 3. | Replace gas regulator |
|
|
|
|
|
Slight smoke or odor during initial operation | 1. | Not enough air | 1. | Check burner for dirt and debris. If |
|
|
|
| found, clean burner (see Cleaning and |
|
|
|
| Maintenance, page 20) |
| 2. | Gas regulator defective | 2. | Replace gas regulator |
| 3. | Residues from manufacturing processes | 3. | Problem will stop after a few hours of |
|
| and logs curing |
| operation |
|
|
|
|
|
Heater produces a whistling noise when | 1. | Turning control knob to HI position | 1. | Turn control knob to LO position and |
burner is lit |
| when burner is cold |
| let warm up for a minute |
| 2. | Air in gas line | 2. | Operate burner until air is removed from |
|
|
|
| line. Have gas line checked by local |
|
|
|
| natural gas company |
| 3. | Air passageways on heater blocked | 3. | Observe minimum installation clear- |
|
|
|
| ances (see pages 7 through 9) |
| 4. | Dirty or partially clogged burner orifice | 4. | Clean burners (see Cleaning and Mainte- |
|
|
|
| nance, page 20) or replace burner orifice |
|
|
|
|
|
Moisture/condensation noticed on windows | 1. | Not enough combustion/ventilation air | 1. | Refer to Air for Combustion and Venti- |
|
|
|
| lation requirements (pages 4 through 6) |
|
|
|
|
|
Dark residue on logs or inside of fireplace | 1. | Improper log placement | 1. | Properly locate logs (see Installing Logs, |
|
|
|
| page 14) |
| 2. | Drafts or other air currents affecting | 2. | Eliminate source of drafts around heater |
|
| flame pattern |
|
|
| 3. | Air holes at burner inlet blocked | 3. | Clean out air holes at burner inlet. Peri- |
|
|
|
| odically repeat as needed |
| 4. | Burner flame holes blocked | 4. | Remove blockage or replace burner |
|
|
|
|
|
White powder residue forming within burner box or on adjacent walls or furniture
1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue
1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products
www.desatech.com
18 | 105191 |