Desa FVF24N Fireplace Manufacturers Incorporated, Unvented Natural Gas Log Heater, Installation

Models: and FVF30N FVF24N FVF18N

1 24
Download 24 pages 95 b
Page 14
Image 14
INSTALLING LOGS

FIREPLACE MANUFACTURERS INCORPORATED

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

INSTALLING LOGS

One PieceWARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Cutout in CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 16. Make sure bottom of front log is in front of “U”- shaped cutout in center of chassis (see Figure 16). Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner parts.

2.Place lava rock on fireplace floor around base of heater.

One Piece

Log Set

Burner

Chassis

"U"-shaped

Cutout in

Chassis

Figure 16 - Installing Heat Majic™ One- Piece Log Set

Burner

One Piece

ports

Log Set

Figure 17 - Installing Heat Majic™ One- Piece Log Set (Top View)

14

105191

Page 14
Image 14
Desa FVF24N Fireplace Manufacturers Incorporated, Unvented Natural Gas Log Heater, Installation, Continued, Burner, ports