UNVENTED
INSTALLATION
Continued
OPTIONAL BLOWER ASSEMBLY INSTALLATION
Proper installation of the blower system is required to insure that the maximum dis- charge of air can be delivered through the louvers on each side of the fireplace.
Note: You may perform this installation from either side of the fireplace. The lower door panels are removable from both sides of the firebox for better access.
1.Remove the blower assembly from the packaging and inspect the fan and wir- ing for damage. If any wiring is loose or damaged, return the assembly for exchange to your dealer or distributor.
2.Remove the 2 screws located at the top of the lower door panel. Slide door panel forward and up to remove tabs on panel from locating slots in firebox (see Figure 16).
3.Locate the two strips of hook & loop mounting strips on one side of the base of the lower compartment. Align the mounting strips on blower with mount- ing strips on base of firebox.
4.Install blower housing with exhaust out- let ports directed upwards along inner side wall of lower compartment. The blower outlets must be installed flush to the outer cabinet for air to flow properly.
5.Apply gentle force between hook & loop mounting strips to seat blower.
6.Remove control knob and lock nut from blower speed control shaft.
7.Place speed control shaft through 3/8" hole provided in right side of lower door panel removed in step 2.
8.While supporting speed control hous- ing, secure shaft in panel hole with lock nut. Place control knob on shaft.
9.Plug blower power cord into receptacle located in lower firebox compartment. Check to make sure there are no for- eign objects in blower wheel.
Operating Optional Blower GA3500A
Light your gas appliance with the blower off. After about 10 minutes, turn the blower on to deliver heated air out the top louvers. The blower features a variable control which allows you to select the blower speed you desire.
Note: Periodically check the louvers of the firebox and remove any dust, dirt, or ob- structions.
Receptacle
Blower
Speed
Control
Shaft
Lock Nut | Hook & Loop | |
Control Knob | ||
Mounting Strips |
Locating
Slot
Locating Holes
Door
Panel
10.Turn blower on and check for proper operation.
WARNING: Never touch the blower wheel while in operation.
11.Turn blower off before continuing.
12.Replace lower door panel by inserting tabs on bottom of panel into locating slots on firebox. Push door panel into an upright position and secure with screws removed in step 2.
Figure 18 - Installing Optional Blower GA3500A
Locating
Slot
Figure 16 - Removing Lower Door Panel
|
| FIELD WIRE |
| |
| BLK | BLK | INCOMING | |
|
|
| ||
|
|
| 120V AC | |
BLOWER | WHT | WHT (FUSE BOX | ||
| RECEPTACLE |
| OR | |
| GRN | BREAKER) | ||
|
|
| ||
VARIABLE | GRN | GND |
| |
ELECTRICAL RATING: |
| |||
SPEED | CONNECTORS | |||
CONTROL | 120v, 60Hz, 0.9A | |||
(NOT SUPPLIED) | ||||
|
|
Note: If any of the original wire must be replaced, it must be replaced with type TEW minimum 16GA copper wire rated at 105°C
Figure 17 - Optional Blower Wiring Diagram
12 | 105163 |
|