HEAT DEFLECTIVE HOOD INSTALLATION

OWNER’S MANUAL

INSTALLATION

Continued

HEAT DEFLECTIVE HOOD INSTALLATION

The factory supplied heat deflective hoods must be installed inside the fireplace open- ings on all three sides for the safe operation of the unit as shown in Figure 19.

1.Remove protective covering from hoods.

2.Position deflective hood into opening on one side of the firebox and secure to the top of the opening using screws provided.

3.Secure the ends of the hood to the fire- box using two screws (provided) for each side.

4.Repeat steps 2 and 3 to install hoods on the remaining side and end of firebox.

OPERATING GUIDELINES & MAINTENANCE INSTRUCTIONS CAUTION: Do not clean hood with abrasive cleanser. Use only regular household cleaners and a smooth cloth.

Front Hood

(Typical Each Side)

OPERATING GUIDELINES & MAINTENANCE INSTRUCTIONS

When lit for the first time, a vent-free log heater will emit a slight odor for about an hour or two. This is a normal occurrence which is due to the "curing" of the logs and the "burn-in" of internal paints and lubri- cants used in the manufacturing process.

Keep control compartments, logs, burners, and areas surrounding the logs clean by vacu- uming or brushing at least twice a year. Temporary removal of the log set may ease the cleaning of the burner and pilot assembly. In cleaning, take care not to alter the settings on the pilot assembly. See the operating instructions supplied with your vent-free log heater for additional cleaning instructions.

Manual background WARNING: Logs can be very hot! Allow logs to cool before handling.

IMPORTANT: Turn off the gas supply at the external shutoff valve before servicing appliance. Any safety screen or guard re- moved for servicing must be replaced prior

Manual background WARNING: Children and adults should be alerted to the hazards of high surface tempera- tures and to stay away to avoid burns or clothing ignition. Young children should be carefully su- pervised when they are in the same room as the appliance.

For lighting and operating this vent-free firebox, please refer to the vent-free gas logs manufacturer’s instruction manual.

Corner Post

2 Screws

Each End of

Hood

3 Screws (Top)

to operating the appliance.

Installation and repair should be done by a qualified person. The appliance should be inspected before use and at least annually by a professional service person. More fre- quent cleaning may be required due to ex- cessive lint from carpeting, pet hair, etc. It is imperative that the control compartments, burners and circulating air passageways of the appliance be kept clean.

Figure 19- Typical Hood Installation (Both Sides)

105163

13

 

Page 13
Image 13
Desa FBPS Operating Guidelines & Maintenance Instructions, Continued, Heat Deflective Hood Installation