OWNER’S MANUAL
SPECIFICATIONS
Output Rating (Btu/Hr) | 70,000 |
Fuel Use Only Kerosene or No. 1 Fuel Oil
Fuel Tank Capacity (U.S. Gal.) |
| 5.0 |
Fuel Consumption (Gal. Per Hr.) | .52 | |
Electric Requirements | 120 V/60 Hz | |
Amperage (Normal Run) |
| 2.8 |
Hot Air Output (CFM) |
| 360 |
Motor RPM |
| 3440 |
Motor HP |
| 1/8 |
Shipping Weight |
|
|
(Approximate Pounds) |
| 36 |
Heater Weight without Fuel |
|
|
(Approximate Pounds) |
| 31 |
WIRING DIAGRAM
| Ignitor | Yellow | Ignitor | |
|
| |||
Yellow | ||||
Red | Motor | |||
|
|
Power Plug | Motor Green | Ignition Control | |
Assembly | |||
120V/60Hz |
| ||
|
| ||
Green | Black | AC Hot (L1) | |
| |||
| White | AC Neutral (L2) | |
| White | Motor Return | |
|
| Ignitor | |
| Blue | Photocell | |
| Photocell | Photocell | |
| Blue |
Figure 19 - Wiring Diagram
ACCESSORIES
Purchase accessories and parts from your nearest dealer or service center. If they can not supply these accessories or parts, either contact your nearest Parts Central or DESA International for referral information. Parts Centrals are listed in the Authorized Service Center booklet supplied with heater.
DESA International P.O. Box 90004 Bowling Green, KY
1-800-972-7879 Parts Department
AIR GAUGE KIT - HA1180
Special tool to check pump pressure.
A 008
IGNITION CONTROL ASSEMBLY/PHOTOCELL TESTER - HA1170
Special tool used to test the ignition control assembly and photocell.
HEAVY DUTY WHEELS AND HANDLE KIT - HA1202
For heavy duty applications. Makes your heater even more portable and convenient.
STANDARD WHEELS AND HANDLE KIT - HA1206
Makes heater even more portable and con- venient. Easy to assemble.
THERMOSTAT KIT - HA1210
Keeps your building at the temperature you select day and night. Helps economize on fuel.