TROUBLESHOOTING

70,000 Btu/Hr H.S.I. Series

PORTABLE FORCED AIR HEATERS

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

FAULT CONDITION WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

FAULT CONDITION

POSSIBLE CAUSE

REMEDY

Motor does not start five seconds after heater

1. No power to heater

1. Check circuit breaker in electrical panel

is plugged in

 

 

 

 

WARNING: High voltage!

 

 

 

 

 

 

 

 

2.Bad electrical connection between mo- tor and ignition control assembly or ig- nition control assembly and power cord

3.Blown fuse on ignition control assembly

4.Binding pump rotor

5.Defective ignition control assembly

6.Defective motor

2.Check all electrical connections. See Wiring Diagram, page 11

3.See Ignition Control Assembly, page 8

4.If fan does not turn freely, see Pump Rotor, page 10

5.Replace ignition control assembly

6.Replace motor

Motor starts and runs but heater does not ignite

1.No fuel in tank

2.Pump pressure incorrect

3.Dirty fuel filter

4.Obstruction in nozzle

5.Water in fuel tank

1.Fill tank with kerosene

2.See Pump Pressure Adjustment, page 7

3.See Fuel Filter, page 8

4.See Nozzle Assembly, page 9

5.Drain and flush fuel tank with clean kerosene. See Storing, Transporting, or Shipping, page 5

POSSIBLE CAUSEREMEDY WARNING: High voltage!

6.

Bad electrical connection between igni-

6.

Check electrical connections. See Wir-

 

tor and ignition control assembly

 

ing Diagram, page 11

7.

Defective ignitor

7.

Replace ignitor, see page 8

8.

Defective ignition control assembly

8.

Replace ignition control assembly

Heater ignites but ignition control assembly shuts heater off after a short period of time

1.Pump pressure incorrect

2.Dirty air intake, air output, and/or lint filter

3.Dirty fuel filter

4.Obstruction in nozzle

5.Photocell assembly not properly in- stalled (not seeing the flame)

1.See Pump Pressure Adjustment, page 7

2.See Air Output, Air Intake, and Lint Fil- ters, page 7

3.See Fuel Filter, page 8

4.See Nozzle Assembly, page 9

5.Make sure photocell boot is properly seated in bracket

WARNING: High voltage!www.desatech.com WARNING: High voltage!

6.

Dirty photocell lens

6.

Clean photocell lens

7.

Bad electrical connection between pho-

7.

Check electrical connections. See Wir-

 

tocell and ignition control assembly

 

ing Diagram, page 11

8.

Defective photocell

8.

Replace photocell

9.

Defective ignition control assembly

9.

Replace ignition control assembly

www.desatech.com

6

103685

Page 6
Image 6
Desa B70D Troubleshooting, Fault Condition, Possible Cause, Remedy, WARNING High voltage, 70,000 Btu/Hr H.S.I. Series

FAQ

How do I troubleshoot a motor that does not start five seconds after the heater is plugged in?

Check for possible causes such as no power to the heater, bad electrical connections, blown fuse on the ignition control assembly, or binding pump rotor. Follow the recommended remedies provided in the manual.

What should be done if the heater ignites but the ignition control assembly shuts it off after a short period of time?

Check for issues related to pump pressure, dirty filters, nozzle obstruction, or improperly installed photocell assembly. Clean the photocell lens and check for any bad electrical connections as per the manual's instructions.

Where can I find the wiring diagram and instructions for replacing the ignition control assembly?

Refer to the specific page numbers in the manual for detailed information on checking electrical connections, wiring diagrams, and replacing the ignition control assembly.