IF GAS LEAK OCCURS

IF GAS LEAK OCCURS

SPECIFICATIONS

!WARNING

If you detect a gas leak, turn off propane supply at once. Ventilate the area. Wait until five minutes after propane odor is not present. Follow steps below to check for gas leak.

!WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

1.After turning off propane supply and ventilating area, unplug heater power cord.

2.Turn propane supply on.

3.Apply a mixture of liquid soap and water to hose and connections between propane tank(s) and heater inlet. Bubbles forming show a leak.

4.Turn propane supply off and ventilate the area. Repair leak.

5.Wait until five minutes after propane odor is not present before restarting heater.

6.If you cannot repair leak, contact you local service center.

Model

BLP35ES

Electrical Input

220/240 volt, 50 hertz, 55 watts IP20

Maximum Input, net

10.3 KW at 27 millibar

Regulator Output

27 millibar

Burner Rate

10.3 KW, 796 g/hr

Supply Pressure (min.)

2 bar

Ventilation

260 cm2

Room Size

103 cubic meters

Air Delivery Class

Type A

Temperature Range for Heater Operation

-29° C to 29° C*

*When running heater in temperatures above 29° C, high internal temperatures may cause thermal limit device to shut down heater.