INSTRUCTIONS WHEN OFFSET OF CHIMNEY IS

 

 

 

OFFSETS AND RISE

 

 

 

 

NEEDED

 

 

 

 

 

 

 

A

B

48

36

18

12

A

B

48

36

18

12

12S

 

 

To Install Elbows

 

 

 

 

 

 

 

 

 

 

 

 

 

4 3/8

16 3/8

 

 

 

 

41 1/4

80 1/4

 

1

1

1

1

1. To achieve desired offset, you may install combinations of 12",

 

 

 

 

 

 

 

 

 

 

 

 

 

9 3/4

25 1/2

 

 

 

1

45

86 3/4

 

2

 

 

1

18", 36", and 48" lengths of double wall pipe (see Offsets and

 

 

 

 

 

 

 

 

 

 

 

 

 

12 3/4 30 3/4

 

 

1

 

46 3/4 89 1/2

1

 

1

1

1

Rise chart and Figures 18 and 20).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Chimney weight above offset rests on return elbow. Straps must

15

34 3/4

 

 

 

2

51

97

1

1

 

 

1

be securely nailed to rafters or joists (see Figure 19, Details A

18

40

 

 

1

1

53 1/4

101

 

2

1

 

1

and B).

 

 

 

 

 

 

 

 

 

 

 

 

 

21 1/4

46 1/4

 

1

 

 

56 1/4 106 1/4

2

 

 

 

1

3. Maximum length of pipe between supports (return elbow or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23 3/4

49 1/4

 

 

1

2

59 1/4 111 1/2

1

1

1

 

1

C12S-8DM) is 6’ of angled run. Maximum of two (2) 6’ angled

 

 

 

run sections per chimney system (see Figure 20).

27 3/4

56 3/4

1

 

 

 

61 3/4 115 1/2

2

 

 

1

1

NOTE: ANY OFFSET GREATER THAN 6 FEET MUST USE A

 

 

 

 

 

 

 

 

 

 

 

 

30

60 3/4

 

1

1

 

64 3/4 120 3/4

2

 

1

 

1

C12S-8DM, ALSO FOR STRAIGHT RUN OVER 30 FT. LEVEL.

 

 

 

 

 

 

 

 

 

 

 

 

 

33

66

1

 

 

1

68 1/4

127

1

2

 

 

1

 

 

 

 

 

 

 

 

36

71

1

 

1

 

70

130

2

 

1

1

1

 

 

38 1/4

75

2

74 1/4 137 1/2

1

2

1

1

 

 

 

 

 

76 3/4141 1/2

1

2

1

1

 

 

 

 

 

79 3/4146 3/4

 

4

 

1

 

B

 

CEILING

 

 

 

 

 

 

 

 

SUPPORT

 

 

 

 

 

 

 

 

 

PIPE

 

2"

 

 

SEE

 

 

 

 

C12S-8DM

 

 

 

 

 

 

 

 

MINIMUM

 

 

 

 

 

 

 

 

 

 

DETAIL A

 

 

 

 

 

 

 

 

 

 

 

 

 

ANGLE

 

 

 

 

 

 

 

 

 

FIRESTOP

 

 

 

 

 

 

 

 

 

 

 

 

SEE

 

A

 

 

DETAIL B

 

 

DETAIL B

 

 

 

 

 

 

 

 

 

 

All joints between offset shall be secured with two screws

 

 

 

 

 

 

 

 

only on the outer pipe and shall not penetrate the inner

 

 

 

 

 

 

 

 

stainless. See illustration above.

 

 

 

 

 

 

 

 

 

Figure 18

 

 

 

RETURN

 

 

 

 

 

 

 

 

ELBOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DETAIL A

 

 

 

 

 

 

 

 

Figure 19

 

 

 

 

 

 

 

RETURN

 

RETURN

 

 

 

 

 

 

 

ELBOW

 

ELBOW

 

 

 

 

 

 

 

 

 

 

 

CEILING

 

 

RETURN

 

6' MAX

 

6' MAX

 

 

SUPPORT

 

 

 

OFFSET

 

 

 

 

ELBOW

 

 

 

PIPE

 

 

 

OFFSET

 

 

 

 

 

 

 

 

 

 

 

 

 

ELBOW

ELBOW

 

 

 

C12S-8DM

 

 

 

 

 

 

 

 

 

 

6' MAX

 

 

RETURN

 

 

RETURN

 

 

 

ELBOW

 

ELBOW

6' MAX

 

 

 

 

 

 

 

 

 

 

 

6' MAX

OFFSET

6' MAX

 

OFFSET

OFFSET

 

 

ELBOW

 

 

ELBOW

 

 

ELBOW

 

 

 

 

 

 

 

 

 

A

B

 

C

Figure 20

55951

7

Page 7
Image 7
Desa C42EC2 installation instructions To Install Elbows, C12S-8DM, Also for Straight RUN Over 30 FT. Level