Desa VS30NRA, CFS18NRA, VS24NRA, VS18NRA Connecting To Gas Supply, Installation, Continued

Models: VS30NRA VS18NRA VS24NRA CFS18NRA

1 26
Download 26 pages 39.32 Kb
Page 11
Image 11
CONNECTING TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

6.Attach base to fireplace floor using masonry screws (in hardware package).

7.Connect to gas supply. See Connect- ing To Gas Supply.

Gas Control

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

Masonry

Screw

Masonry

Screw

Figure 12 - Attaching Base to Fireplace Floor

CONNECTING TO GAS SUPPLY

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Manual backgroundCAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas vol- ume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

We recommend that you install a sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings.

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

Tee

Joint

Pipe

Nipple

A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*

Approved Flexible Gas Hose (if allowed by local codes)

Gas Control

Sediment Cap Trap

3" Minimum

Figure 13 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

** Minimum inlet pressure for purpose of input adjustment.

Continued

104416

11

Page 11
Image 11
Desa VS30NRA, CFS18NRA, VS24NRA, VS18NRA installation manual Connecting To Gas Supply, Installation, Continued