INSTALLATION

Connecting to Gas Supply (Cont.) Connecting Equipment Shutoff Valve to Heater Control

15

INSTALLATION

Continued

We recommend that you install a sediment trap in supply line as shown in Figure 24. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

4.Apply pipe joint sealant lightly to male threads of gas connec- tor attached to flexible gas line/equipment shutoff valve (see Figure 26).

5.Check all gas connections for leaks. See Checking Gas Con- nections, page 16.

6.Replace branch support back into fireplace. Feed flexible gas line into fireplace base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 2.

3" Minimum

PROPANE/LP

From External Regulator (11" W.C. to 14" W.C. Pressure)

Branch

Screen Shipping

Pipe Cap Nipple

Tee

NATURAL

From Gas Meter (5" W.C.

Joint

to 10.5" W.C. Pressure)

 

Support

Screw

Shoulder

Sediment Trap

Figure 24 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 29.

CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1. Remove fireplace screen. Remove two screws that hold fire-

place screen in place for shipping. These screws are located

Screw

Flexible

Gas Line

Screen

Figure 25 - Removing Log Base Assembly From Fireplace

 

near top of screen. Discard screws. Lift fireplace screen up

 

and pull out to remove.

2.

Remove screws that attach branch support to fireplace (see

 

Figure 25). Carefully lift up branch support and remove from

 

fireplace (see Figure 25).

3.

Route flexible gas line, included, from fireplace control to

 

equipment shutoff valve through side or rear access holes

 

in outer casing.

NOTICE: Most building codes do not permit con- cealed gas connections. A flexible gas line is pro- vided to allow accessibility from the fireplace (see

To Fireplace

Gas Regulator

Flexible Gas Line from Fireplace Gas Regulator Provided with Fireplace

Equipment Shutoff Valve Provided by Installer

PROPANE/LP

To External

Regulator

NATURAL

To Gas Supply

Figure 25). The flexible gas supply line connection to the equipment shutoff valve should be accessible.

Figure 26 - Attaching Flexible Gas Line to Equipment Shutoff Valve