Desa CGCFTP CGCFTN Mantel Clearances for BUILT-IN Installation, Optional Mantel Installation

Models: CGCFTP CGCFTN

1 30
Download 30 pages 30.66 Kb
Page 10
Image 10

10

INSTALLATION

Built-In Fireplace Installation (Cont.) Mantel Clearances for Built-In Installation Optional Mantel Installation

INSTALLATION

Continued

WARNING: Do not allow any combustible materi- als to overlap the firebox front facing.

IMPORTANT: Noncombustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any necessary openings like louvered slots.

WARNING: Do not allow noncombustible materials to cover any necessary openings like louvered slots.

WARNING: Never modify or cover the louvered slots on the front of the firebox.

WARNING: Use only noncombustible mortar or adhesives when overlapping the front facing with noncombustible facing material.

 

10"

 

Note: All vertical

8"

 

 

6"

 

 

measurements are

 

 

from top of fireplace

2

1

/2"

 

opening to bottom of

 

 

 

 

 

 

mantel shelf. All

 

 

 

 

measurements are in

 

 

 

 

inches.

 

 

 

 

Side of

 

 

13"

16"

 

 

 

 

Firebox

Mantel Shelf

19"

 

21"

 

 

 

 

MANTEL CLEARANCES FOR BUILT-IN INSTALLATION

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

raise the mantel to an acceptable height

remove the mantel

Figure 12 - Minimum Mantel Clearances for Built-In Installation

OPTIONAL MANTEL INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3450T, pages 11 through 13).

1.Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside.

2.Place fireplace on wood base.

3.Place mantel around fireplace/base assembly.

4.Assemble brass trim kit. See Assembling Brass Trim, page 11.

5.Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 13).

Shoulder Screws

Hole for 3" Wood Screw for Attaching Fireplace to Mantel

 

Hole for 3"

 

Wood Screw

Assembled Brass Trim

for Attaching

Fireplace to

 

 

Wooden Base

Figure 13 - Attaching Brass Trim to Fireplace

For..com

111044-01C

Page 10
Image 10
Desa CGCFTP CGCFTN installation manual Mantel Clearances for BUILT-IN Installation, Optional Mantel Installation