INSTALLING
Mantel Shelf
Continued
| 12" |
|
|
| 10" |
|
|
| 8" |
|
|
| 6" |
|
|
| 2 1/2" |
|
|
Minimum Non- |
|
|
|
Combustible |
|
|
|
Material | 8" | 12" | 15" |
| |||
| Min. |
|
|
| Hood | Distances to | |
| (GA6050, GA6052) | ||
| Underside of | ||
|
| ||
|
| Mantel |
18"
Underside of
Mantel Shelf
All minimum distances are in inches
Log Set
20" 24" Model
Top of Fireplace Opening
Figure 7 - Minimum Mantel Clearances When Using Hood
If your installation does not meet the above minimum clearances, you must:
•operate the logs only with the flue damper open, OR
•raise the mantel to an acceptable height, OR
•remove the mantel.
Floor Clearances
A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
14"
Combustible Material
12
Min.
Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level
B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).
Hearth
Combustible Material
5"
Min.
Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring
102828