INSTALLING
Continued
10
NOTICE
You may use this heater as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open,
Minimum Non Combustible Material Clearances
If Not Using Mantel
Note: If using a mantel, go to page 11. If not using a mantel, follow the informa- tion on this page.
You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8" up. If non combustible material is less than 12", you must install the fireplace hood accessory. See chart below and Figure 5 for minimum clearances.
IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.
Requirements for | |
Material Distance (A) | Safe Installation |
|
|
12" or more | Non combustible material OK. |
Between 8" and 12" | Install fireplace hood acessory (GA6050 or |
| GA6052, see Accessories, page 29). |
Less than 8" | |
| at least 8". See Between 8" and 12", above. If |
| you cannot extend material, you must operate |
| heater with flue damper open. |
|
|
Heat Resistant
Material
(A)
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace