OWNER’S MANUAL
OPERATING
HEATER
Continued
IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down.
IMPORTANT: The
3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used when the sta- tus button is pressed.
4.To turn the burners off when operat- ing in the manual mode, press the OFF button. If operating in the auto mode, press the MAN button, then press the OFF button. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 34 shows a correct pilot flame pattern. Figure 35 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 35
• | turn heater off (see To Turn Off Gas to |
| Appliance, page 16) |
• | seeTroubleshooting, pages 19 through 21 |
Flame Adjustment Knob | Control Knob in On Position | ||||
| IH |
|
| IL | |
ON |
|
| F | P | O |
|
| O |
|
| T |
OFF |
|
|
| O | |
|
|
|
| ||
|
|
|
| N | |
REMOTE |
|
|
|
| |
LO |
|
|
|
| |
|
|
|
|
|
Selector Switch in Remote Position
Figure 32 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Pilot Burner
Thermocouple
Shows Temperature Setting
Allows Burners to be Turned On and Off with the
The Log Heater Will Automati- cally Cycle Between Pilot and the Heat Setting That Has Been Selected.
HI
TEMP
MAN LO ON
AUTO OFF
STATUS
Increases Room Temperature
Decreases Room Temperature
Turns Burners On and Off
Shows Current Operation Mode
Figure 34 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 35 - Incorrect Pilot Flame Pattern
Figure 33 - Thermostat Hand-Held Remote Control Unit Selections
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.