Cisco UCS C220 Server Installation and Service Guide
Covers Server Generation M3 April 12
Cisco Systems, Inc 170 West Tasman Drive San Jose, CA
800 553-NETS Fax 408
Reorient or relocate the receiving antenna
Installing the Server
Initial Server Setup
NIC Modes and NIC Redundancy Settings
Using the Clear CMOS Header J37
Maintaining the Server
DIMM Replacement Procedure
Server Configuration Utility
PCIe Slots
Physical Specifications
Launching the LSI Embedded RAID Configuration Utility C-11
Installing a Trusted Platform Module
Server Specifications
Cisco UCS C220 Server Installation and Service Guide
Installation for Cisco UCS Integration D-1
For More Information C-23
Contents
Specifications
Installing the Server
Server Specifications
Power Cord
viii
Audience
Documentation Feedback
Conventions
Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA
Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo
OL-25760-01
Preface Cisco UCS C220 Server Installation and Service Guide
Obtaining Documentation and Submitting a Service Request
xiii
OL-25760-01
Preface Cisco UCS C220 Server Installation and Service Guide
C H A P T E R
External Features Overview
External Features Overview, page Summary of Server Features, page
Overview
HDD4
HDD1
HDD2
HDD3
Summary of Server Features
PCIe2
PCIe1
Power
See Replacing a PCIe Card, page 3-33 for slot specifications
page
Considerations, page C-1
System BIOS and CIMC Firmware, page
Installing the Server
Preparing for Server Installation, page
Installing the Server In a Rack, page Initial Server Setup, page
Unpacking and Inspecting the Server
Equipment Requirements, page Slide Rail Adjustment Range, page
Preparing for Server Installation
Installation Guidelines
Installation Guidelines, page Rack Requirements, page
Slide Rail Adjustment Range
Rack Requirements
Equipment Requirements
Installing the Server In a Rack
Figure 2-3 Attaching a Slide-Rail Assembly
Flange on rear of outer left slide rail
Step 5 Continue with the “Initial Server Setup” section on page
NIC Modes and NIC Redundancy Settings, page
Initial Server Setup
Connecting and Powering On the Server Standalone Mode
Connecting and Powering On the Server Standalone Mode, page
Active-active-All Ethernet ports are utilized simultaneously
Step 4 Connect to the CIMC for server management. Connect Ethernet cables from your LAN to the server, using the ports that you selected by your NIC Mode setting in Step 3. The Active-active and Active-passive NIC redundancy settings require you to connect to two ports
2-10
2-11
NIC Modes and NIC Redundancy Settings
See the Cisco UCS C-Series Rack-Mount Server BIOS Upgrade Guide
System BIOS and CIMC Firmware
Updating the BIOS and CIMC Firmware
Accessing the System BIOS, page
2-13
Accessing the System BIOS
Header Locations on the Motherboard
Service Headers and Jumpers
Using the BIOS Recovery Header J41, page
Using the Clear CMOS Header J37, page
Using the BIOS Recovery Header J41
Procedure 1 Reboot With recovery.cap File
2-15
2-16
Procedure 2 Use Recovery Jumper and recovery.cap File
2-17
Using the Clear CMOS Header J37
OL-25760-01
2-18
Chapter 2 Installing the Server Service Headers and Jumpers
Cisco UCS C220 Server Installation and Service Guide
Maintaining the Server
Server Configuration Utility
Preparing for Server Component Installation, page
Installing or Replacing Server Components, page
Status LEDs and Buttons
Internal Diagnostic LEDs, page
Power button/Power status LED
Off-There is no AC power to the server
LED Name
State
Front Panel LEDs, Definitions of States continued
Rear Panel LEDs and Buttons
Figure 3-2 Rear Panel LEDs and Buttons
Rear Panel LEDs, Definitions of States
LED Name
State
Rear Panel LEDs, Definitions of States continued
Amber-Component has failed
Internal Diagnostic LEDs
Internal diagnostic LEDs all
Off-Component is functioning normally
Required Equipment
Preparing for Server Component Installation
Shutting Down and Powering Off the Server
Shutting Down and Powering Off the Server, page
Release button
Removing and Replacing the Server Top Cover
Front cover panel
Rubber finger pads two
Figure 3-5 Replaceable Component Locations
Replaceable Component Locations
Serial Number Location
Color-Coded Touch Points
3-10
Replacing a SCU Upgrade ROM Module, page
Installing or Replacing Server Components
Replacing the Motherboard RTC Battery, page
Installing a Trusted Platform Module, page
3-12
Drive Population Guidelines, page Drive Replacement Procedure, page
Replacing Hard Drives or Solid State Drives
Drive Population Guidelines
HDD2
Drive Replacement Procedure
3-13
HDD1
3-14
Replacing a Drive Backplane
FAN2
3-15
Figure 3-9 Replacing the Drive Backplane
FAN1
Replacing Fan Modules
3-16
Figure 3-10 Fan Module Numbering
Chapter 3 Maintaining the Server
3-17
Installing or Replacing Server Components
Cisco UCS C220 Server Installation and Service Guide
DIMM Slot Numbering
DIMM Replacement Procedure, page
Replacing DIMMs
Memory Performance Guidelines and Population Rules
CPU1 CPU2
DIMM Population Rules
3-19
Front of Server
Mix Across Single Channel?
Enabling Low-Voltage DIMM Operation Power Saving Mode
3-20
DIMM Parameter Mixed
Number of DIMMs
DIMM Sparing and Rank Sparing
Memory Mirroring
3-21
Replacing DIMMs
DIMM Replacement Procedure
Identifying a Faulty DIMM
Identifying a Faulty DIMM, page Replacing DIMMs, page
Replacing CPUs and Heatsinks
3-23
Step
3-24
Figure 3-13 CPU Heatsink and Socket
Figure 3-14 Protective Cap Removal Tool
Arrow on tool
3-25
Figure 3-16 CPU and Pick-and-Place Tool on Pedestal
3-26
f. Replace the top cover
3-27
3-28
Replacing the Motherboard RTC Battery
RTC battery holder on motherboard
Replacing a Mezzanine Card
3-29
PCIe2
3-30
Figure 3-19 Replacing the Mezzanine Card
PCIe1
PCIe
Replacing a PCIe Riser
PCIe
3-31
Chapter 3 Maintaining the Server
3-32
Installing or Replacing Server Components
Cisco UCS C220 Server Installation and Service Guide
PCIe Slots, page Replacing a PCIe Card, page
Installing Multiple PCIe Cards and Resolving Limited Resources, page
Replacing a PCIe Card
PCIe Slots
3-34
Replacing a PCIe Card
Cisco UCS C220 Requirements for Virtual Interface Cards
Special Considerations for Cisco UCS Virtual Interface Cards
RAID Controller Card Cable Routing
3-35
Resolving Insufficient Memory Space to Execute Option ROMs, page
Installing Multiple PCIe Cards and Resolving Limited Resources
See also Factory-Default Option ROM Settings, page C-4
Resolving Insufficient Memory Space to Execute Option ROMs
3-37
Resolving Insufficient 16-Bit I/O Space
Cisco Flexible Flash Card Replacement Procedure, page
Overview of the Pre-Installed Cisco Flexible Flash Card
Overview of the Pre-Installed Cisco Flexible Flash Card, page
Booting a Cisco Flexible Flash Virtual Drive, page
Booting the Hypervisor VD, page
Booting a Cisco Flexible Flash Virtual Drive
Booting the Cisco SCU and Cisco HUU Software VDs
Booting the Cisco SCU and Cisco HUU Software VDs, page
3-40
Cisco Flexible Flash Card Replacement Procedure
Booting the Hypervisor VD
Monitoring and Managing a Cisco Flexible Flash Card
Step 2 Install a Cisco Flexible Flash card
3-41
3-42
Replacing the LSI RAID Battery Backup Unit or SuperCap Power Module
Chapter 3 Maintaining the Server
3-43
Installing or Replacing Server Components
Cisco UCS C220 Server Installation and Service Guide
3-44
Installing a Trusted Platform Module
PSU2
3-45
Figure 3-25 TPM Socket Location on Motherboard
CPU1
3-46
b. Set TXT Support to Enabled
d. Set Intel R VT and Intel R VT-d to Enabled
Replacing a SCU Upgrade ROM Module
3-47
Figure 3-26 SCU Upgrade ROM Module Retention Feature
Replacing a Software RAID Key Module
3-48
Figure 3-27 Software RAID Key Module Retention Feature
3-49
Replacing Power Supplies
3-50
Enabling or Disabling the Internal USB Port
Environmental Specifications, page A-2 Power Specifications, page A-3
Server Specifications
Physical Specifications
Physical Specifications, page A-1
Environmental Specifications
450W Power Supply, page A-3 650W Power Supply, page A-3
Power Specifications
450W Power Supply
650W Power Supply
Appendix A Server Specifications Power Specifications
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Figure B-1
Power Cord Specifications
Supported Power Cords and Plugs
A P P E N D I X B
Figure B-10
Figure B-7
Figure B-8
Figure B-9
Connector
AC Power Cord Illustrations
Connector
Appendix B Power Cord Specifications Supported Power Cords and Plugs
M2511
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Cisco UCS C220 Server Installation and Service Guide
I/3G
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Cisco UCS C220 Server Installation and Service Guide
Plug
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Cisco UCS C220 Server Installation and Service Guide
Cisco UCS C220 Server Installation and Service Guide
CAB-C13-C14-2M, Jumper Power Cord 2 m
CAB-C13-C14-AC, Jumper Power Cord 3 m
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
A P P E N D I X C
Factory-Default Option ROM Settings, page C-4
RAID Backup Units, page C-5 RAID Controller Migration, page C-6
RAID Controller Considerations
Supported RAID Controllers and Required Cables
Allowed?
Mixing Drive Types in RAID Groups
Mix of Drive Types
in RAID Group
Factory-Default Option ROM Settings
RAID Backup Units
Mixing Drive Types in RAID Groups
Table C-5 Drive Type Mixing in RAID Groups
Migrate to SW RAID Allowed?
RAID Controller Migration
Starting RAID Controller
Migrate to HW RAID Allowed?
Installing LSI MegaSR Drivers For Windows and Linux, page C-11
Enabling the Embedded RAID Controller in the BIOS, page C-10
Disabling the Embedded RAID Controller in the BIOS, page C-11
Launching the LSI Embedded RAID Configuration Utility, page C-11
Notes on Supported Embedded MegaRAID Levels
Installing a SCU Upgrade ROM Module For Embedded RAID SAS Support
Installing a Software RAID Key Module for Embedded RAID 5 Support
Enabling the Embedded RAID Controller in the BIOS
C-10
Microsoft Windows Driver Installation, page C-12
Disabling the Embedded RAID Controller in the BIOS
Launching the LSI Embedded RAID Configuration Utility
Installing LSI MegaSR Drivers For Windows and Linux
Downloading the LSI MegaSR Drivers
Microsoft Windows Driver Installation
Windows Server 2008R2 Driver Installation
Windows Server 2008R2 Driver Installation, page C-12
C-13
Updating the Windows Driver
Installing the Red Hat Linux Driver, page C-16
Linux Driver Installation
Preparing Physical Installation Diskettes For Linux
Preparing Physical Installation Diskettes For Linux, page C-14
C-15
Preparing Installation Disks With a Linux Operating System
dd if=dud-driver version.img of=/dev/fd0
C-16
Installing the Red Hat Linux Driver
C-17
Installing the SUSE Linux Enterprise Server 11 Driver
Step 14 Press OK
C-18
C-19
RAID Controller Cabling
Cable Routing
Cable Routing, page C-19 Cisco UCS C220 Server Cabling, page C-20
Embedded RAID
Cisco UCS C220 Server Cabling
Backplane and Expander Options
SFF 8-Drive Backplane Cabling
Cisco UCS RAID SAS 2008M-8i Mezzanine Card
LSI MegaRAID SAS 9266-8i or 9266CV-8i PCIe Card
C-21
Cisco UCS RAID SAS 2008M-8i Mezzanine Card
LFF 4-Drive Backplane Cabling
C-22
Embedded RAID
For More Information
C-23
Restoring RAID Configuration After Replacing a RAID Controller
OL-25760-01
C-24
Cisco UCS C220 Server Installation and Service Guide
Appendix C RAID Controller Considerations For More Information
A P P E N D I X D
Installation for Cisco UCS Integration
Appendix D Installation for Cisco UCS Integration
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01