Cisco Systems UCSRAID9266CV Replacing Hard Drives or Solid State Drives, 3-12, HDD1, HDD2, HDD3

Models: UCSRAID9266CV C220 9266CV-8i UCSSP6C220E UCUCSEZC220M3S

1 124
Download 124 pages 40.24 Kb
Page 48
Image 48
Replacing Hard Drives or Solid State Drives

Chapter 3 Maintaining the Server

Installing or Replacing Server Components

Replacing Hard Drives or Solid State Drives

This section includes the following information:

Drive Population Guidelines, page 3-12

Drive Replacement Procedure, page 3-13

Drive Population Guidelines

The server has two different drive backplane options:

The Small Form Factor drives version can hold up to eight 2.5-inch hard drives or solid state drives.

The Large Form Factor drives version can hold up to four 3.5-inch hard drives.

The drive-bay numbering is shown in Figure 3-6.

Figure 3-6 Drive Numbering, Small Form Factor

 

 

HDD1

HDD2

HDD3

331695

HDD4

HDD5

HDD6

HDD7

HDD8

 

 

 

 

 

Figure 3-7 Drive Numbering, Large Form Factor

HDD1

HDD2

HDD3

HDD4

331696

Observe these drive population guidelines for optimum performance:

When populating drives, add drives to the lowest-numbered bays first.

Keep an empty drive blanking tray in any unused bays to ensure proper air flow.

You can mix hard drives and SSDs in the same server (the LFF version of the server does not support SSDs). However, You cannot configure a logical volume (virtual drive) that contains a mix of hard drives and SSDs. That is, when you create a logical volume, it must contain all hard drives or all SSDs.

 

Cisco UCS C220 Server Installation and Service Guide

3-12

OL-25760-01

Page 48
Image 48
Cisco Systems UCSRAID9266CV Replacing Hard Drives or Solid State Drives, Drive Population Guidelines, 3-12, HDD1, HDD2