Cisco Systems, Inc 170 West Tasman Drive San Jose, CA
Covers Server Generation M3 April 12
800 553-NETS Fax 408
Cisco UCS C220 Server Installation and Service Guide
Reorient or relocate the receiving antenna
NIC Modes and NIC Redundancy Settings
Initial Server Setup
Using the Clear CMOS Header J37
Installing the Server
Server Configuration Utility
DIMM Replacement Procedure
PCIe Slots
Maintaining the Server
Installing a Trusted Platform Module
Launching the LSI Embedded RAID Configuration Utility C-11
Server Specifications
Physical Specifications
For More Information C-23
Installation for Cisco UCS Integration D-1
Contents
Cisco UCS C220 Server Installation and Service Guide
Server Specifications
Installing the Server
Power Cord
Specifications
Documentation Feedback
Audience
Conventions
viii
Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA
Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo
OL-25760-01
Preface Cisco UCS C220 Server Installation and Service Guide
Obtaining Documentation and Submitting a Service Request
xiii
OL-25760-01
Preface Cisco UCS C220 Server Installation and Service Guide
External Features Overview, page Summary of Server Features, page
External Features Overview
Overview
C H A P T E R
HDD2
HDD1
HDD3
HDD4
Summary of Server Features
PCIe2
PCIe1
page
See Replacing a PCIe Card, page 3-33 for slot specifications
Considerations, page C-1
Power
Preparing for Server Installation, page
Installing the Server
Installing the Server In a Rack, page Initial Server Setup, page
System BIOS and CIMC Firmware, page
Unpacking and Inspecting the Server
Installation Guidelines
Preparing for Server Installation
Installation Guidelines, page Rack Requirements, page
Equipment Requirements, page Slide Rail Adjustment Range, page
Slide Rail Adjustment Range
Rack Requirements
Equipment Requirements
Installing the Server In a Rack
Figure 2-3 Attaching a Slide-Rail Assembly
Flange on rear of outer left slide rail
Step 5 Continue with the “Initial Server Setup” section on page
Connecting and Powering On the Server Standalone Mode
Initial Server Setup
Connecting and Powering On the Server Standalone Mode, page
NIC Modes and NIC Redundancy Settings, page
Active-active-All Ethernet ports are utilized simultaneously
Step 4 Connect to the CIMC for server management. Connect Ethernet cables from your LAN to the server, using the ports that you selected by your NIC Mode setting in Step 3. The Active-active and Active-passive NIC redundancy settings require you to connect to two ports
2-10
2-11
NIC Modes and NIC Redundancy Settings
Updating the BIOS and CIMC Firmware
System BIOS and CIMC Firmware
Accessing the System BIOS, page
See the Cisco UCS C-Series Rack-Mount Server BIOS Upgrade Guide
2-13
Accessing the System BIOS
Using the BIOS Recovery Header J41, page
Service Headers and Jumpers
Using the Clear CMOS Header J37, page
Header Locations on the Motherboard
Using the BIOS Recovery Header J41
Procedure 1 Reboot With recovery.cap File
2-15
2-16
Procedure 2 Use Recovery Jumper and recovery.cap File
2-17
Using the Clear CMOS Header J37
Chapter 2 Installing the Server Service Headers and Jumpers
2-18
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Preparing for Server Component Installation, page
Server Configuration Utility
Installing or Replacing Server Components, page
Maintaining the Server
Power button/Power status LED
Internal Diagnostic LEDs, page
Off-There is no AC power to the server
Status LEDs and Buttons
LED Name
State
Front Panel LEDs, Definitions of States continued
Rear Panel LEDs and Buttons
Figure 3-2 Rear Panel LEDs and Buttons
Rear Panel LEDs, Definitions of States
LED Name
State
Rear Panel LEDs, Definitions of States continued
Internal diagnostic LEDs all
Internal Diagnostic LEDs
Off-Component is functioning normally
Amber-Component has failed
Shutting Down and Powering Off the Server
Preparing for Server Component Installation
Shutting Down and Powering Off the Server, page
Required Equipment
Front cover panel
Removing and Replacing the Server Top Cover
Rubber finger pads two
Release button
Figure 3-5 Replaceable Component Locations
Replaceable Component Locations
Serial Number Location
Color-Coded Touch Points
3-10
Replacing the Motherboard RTC Battery, page
Installing or Replacing Server Components
Installing a Trusted Platform Module, page
Replacing a SCU Upgrade ROM Module, page
Replacing Hard Drives or Solid State Drives
Drive Population Guidelines, page Drive Replacement Procedure, page
Drive Population Guidelines
3-12
3-13
Drive Replacement Procedure
HDD1
HDD2
3-14
Replacing a Drive Backplane
Figure 3-9 Replacing the Drive Backplane
3-15
FAN1
FAN2
Replacing Fan Modules
3-16
Figure 3-10 Fan Module Numbering
Installing or Replacing Server Components
3-17
Cisco UCS C220 Server Installation and Service Guide
Chapter 3 Maintaining the Server
Replacing DIMMs
DIMM Replacement Procedure, page
Memory Performance Guidelines and Population Rules
DIMM Slot Numbering
3-19
DIMM Population Rules
Front of Server
CPU1 CPU2
3-20
Enabling Low-Voltage DIMM Operation Power Saving Mode
DIMM Parameter Mixed
Mix Across Single Channel?
Memory Mirroring
DIMM Sparing and Rank Sparing
3-21
Number of DIMMs
Identifying a Faulty DIMM
DIMM Replacement Procedure
Identifying a Faulty DIMM, page Replacing DIMMs, page
Replacing DIMMs
Replacing CPUs and Heatsinks
3-23
Step
3-24
Figure 3-13 CPU Heatsink and Socket
Figure 3-14 Protective Cap Removal Tool
Arrow on tool
3-25
Figure 3-16 CPU and Pick-and-Place Tool on Pedestal
3-26
f. Replace the top cover
3-27
3-28
Replacing the Motherboard RTC Battery
RTC battery holder on motherboard
Replacing a Mezzanine Card
3-29
Figure 3-19 Replacing the Mezzanine Card
3-30
PCIe1
PCIe2
PCIe
Replacing a PCIe Riser
3-31
PCIe
Installing or Replacing Server Components
3-32
Cisco UCS C220 Server Installation and Service Guide
Chapter 3 Maintaining the Server
Replacing a PCIe Card
Installing Multiple PCIe Cards and Resolving Limited Resources, page
PCIe Slots
PCIe Slots, page Replacing a PCIe Card, page
3-34
Replacing a PCIe Card
RAID Controller Card Cable Routing
Special Considerations for Cisco UCS Virtual Interface Cards
3-35
Cisco UCS C220 Requirements for Virtual Interface Cards
See also Factory-Default Option ROM Settings, page C-4
Installing Multiple PCIe Cards and Resolving Limited Resources
Resolving Insufficient Memory Space to Execute Option ROMs
Resolving Insufficient Memory Space to Execute Option ROMs, page
3-37
Resolving Insufficient 16-Bit I/O Space
Overview of the Pre-Installed Cisco Flexible Flash Card, page
Overview of the Pre-Installed Cisco Flexible Flash Card
Booting a Cisco Flexible Flash Virtual Drive, page
Cisco Flexible Flash Card Replacement Procedure, page
Booting the Cisco SCU and Cisco HUU Software VDs
Booting a Cisco Flexible Flash Virtual Drive
Booting the Cisco SCU and Cisco HUU Software VDs, page
Booting the Hypervisor VD, page
Booting the Hypervisor VD
Cisco Flexible Flash Card Replacement Procedure
Monitoring and Managing a Cisco Flexible Flash Card
3-40
Step 2 Install a Cisco Flexible Flash card
3-41
3-42
Replacing the LSI RAID Battery Backup Unit or SuperCap Power Module
Installing or Replacing Server Components
3-43
Cisco UCS C220 Server Installation and Service Guide
Chapter 3 Maintaining the Server
3-44
Installing a Trusted Platform Module
Figure 3-25 TPM Socket Location on Motherboard
3-45
CPU1
PSU2
3-46
b. Set TXT Support to Enabled
d. Set Intel R VT and Intel R VT-d to Enabled
Replacing a SCU Upgrade ROM Module
3-47
Figure 3-26 SCU Upgrade ROM Module Retention Feature
Replacing a Software RAID Key Module
3-48
Figure 3-27 Software RAID Key Module Retention Feature
3-49
Replacing Power Supplies
3-50
Enabling or Disabling the Internal USB Port
Physical Specifications
Server Specifications
Physical Specifications, page A-1
Environmental Specifications, page A-2 Power Specifications, page A-3
Environmental Specifications
450W Power Supply
Power Specifications
650W Power Supply
450W Power Supply, page A-3 650W Power Supply, page A-3
Appendix A Server Specifications Power Specifications
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Supported Power Cords and Plugs
Power Cord Specifications
A P P E N D I X B
Figure B-1
Figure B-8
Figure B-7
Figure B-9
Figure B-10
Connector
AC Power Cord Illustrations
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Connector
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
M2511
Connector
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
I/3G
Connector
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
Plug
CAB-C13-C14-AC, Jumper Power Cord 3 m
CAB-C13-C14-2M, Jumper Power Cord 2 m
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
RAID Backup Units, page C-5 RAID Controller Migration, page C-6
Factory-Default Option ROM Settings, page C-4
RAID Controller Considerations
A P P E N D I X C
Supported RAID Controllers and Required Cables
Mix of Drive Types
Mixing Drive Types in RAID Groups
in RAID Group
Allowed?
Factory-Default Option ROM Settings
RAID Backup Units
Mixing Drive Types in RAID Groups
Table C-5 Drive Type Mixing in RAID Groups
Starting RAID Controller
RAID Controller Migration
Migrate to HW RAID Allowed?
Migrate to SW RAID Allowed?
Disabling the Embedded RAID Controller in the BIOS, page C-11
Enabling the Embedded RAID Controller in the BIOS, page C-10
Launching the LSI Embedded RAID Configuration Utility, page C-11
Installing LSI MegaSR Drivers For Windows and Linux, page C-11
Notes on Supported Embedded MegaRAID Levels
Installing a SCU Upgrade ROM Module For Embedded RAID SAS Support
Installing a Software RAID Key Module for Embedded RAID 5 Support
Enabling the Embedded RAID Controller in the BIOS
C-10
Launching the LSI Embedded RAID Configuration Utility
Disabling the Embedded RAID Controller in the BIOS
Installing LSI MegaSR Drivers For Windows and Linux
Microsoft Windows Driver Installation, page C-12
Windows Server 2008R2 Driver Installation
Microsoft Windows Driver Installation
Windows Server 2008R2 Driver Installation, page C-12
Downloading the LSI MegaSR Drivers
C-13
Updating the Windows Driver
Preparing Physical Installation Diskettes For Linux
Linux Driver Installation
Preparing Physical Installation Diskettes For Linux, page C-14
Installing the Red Hat Linux Driver, page C-16
C-15
Preparing Installation Disks With a Linux Operating System
dd if=dud-driver version.img of=/dev/fd0
C-16
Installing the Red Hat Linux Driver
C-17
Installing the SUSE Linux Enterprise Server 11 Driver
Step 14 Press OK
C-18
Cable Routing
RAID Controller Cabling
Cable Routing, page C-19 Cisco UCS C220 Server Cabling, page C-20
C-19
Backplane and Expander Options
Cisco UCS C220 Server Cabling
SFF 8-Drive Backplane Cabling
Embedded RAID
Cisco UCS RAID SAS 2008M-8i Mezzanine Card
LSI MegaRAID SAS 9266-8i or 9266CV-8i PCIe Card
C-21
C-22
LFF 4-Drive Backplane Cabling
Embedded RAID
Cisco UCS RAID SAS 2008M-8i Mezzanine Card
For More Information
C-23
Restoring RAID Configuration After Replacing a RAID Controller
Cisco UCS C220 Server Installation and Service Guide
C-24
Appendix C RAID Controller Considerations For More Information
OL-25760-01
A P P E N D I X D
Installation for Cisco UCS Integration
Appendix D Installation for Cisco UCS Integration
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01