Chapter 2 Installing the Server

Service Headers and Jumpers

Using the Clear CMOS Header J37

See Figure 2-5for the location of this header. You can jumper this header to clear the server’s CMOS settings in the case of a system hang. For example, if the server hangs because of incorrect settings and does not boot, use this jumper to invalidate the settings and reboot with defaults.

Caution Clearing the CMOS removes any customized settings and might result in data loss. Make a note of any necessary customized settings in the BIOS before you use this clear CMOS procedure.

Step 1 Power off the server as described in Shutting Down and Powering Off the Server, page 3-7.Step 2 Disconnect all power cords from the power supplies.

Step 3 Slide the server out the front of the rack far enough so that you can remove the top cover. You might have to detach cables from the rear panel to provide clearance.

Caution If you cannot safely view and access the component, remove the server from the rack.

Step 4 Remove the top cover as described in Removing and Replacing the Server Top Cover, page 3-8.Step 5 Move the shorting jumper to pins 2 and 3 of the J37 header (see Figure 2-5).

Step 6 Reinstall the top cover and reconnect AC power cords to the server. The server powers up to standby power mode, indicated when the Power LED on the front panel is amber.

Step 7 Return the server to main power mode by pressing the Power button on the front panel. The server is in main power mode when the Power LED is green.

Note You must allow the entire server, not just the service processor, to reboot to main power mode to complete the reset. This is because the state of the jumper cannot be determined without the host CPU running.

Step 8 Press the Power button to shut down the server to standby power mode, and then remove AC power cords from the server to remove all power.

Step 9 Remove the top cover from the server.

Step 10 Move the shorting jumper from header pins 2 and 3, back to its default position on pins 1 and 2.

Note If you do not move the jumper, the CMOS settings are reset to the default every time that you power-cycle the server.

Step 11 Replace the top cover, replace the server in the rack, replace power cords and any other cables, then power on the server by pressing the Power button.

 

 

Cisco UCS C220 Server Installation and Service Guide

 

 

 

 

 

 

OL-25760-01

 

 

2-17

 

 

 

 

 

Page 35
Image 35
Cisco Systems UCSSP6C220E, UCUCSEZC220M3S, UCSRAID9266CV, 9266CV-8i manual Using the Clear Cmos Header J37

UCSRAID9266CV, C220, 9266CV-8i, UCSSP6C220E, UCUCSEZC220M3S specifications

Cisco Systems offers a range of powerful solutions for data center and enterprise infrastructures, among which are the UCSSP6C220E and UCUCSEZC220M3S, as well as the UCS C220 servers and the 9266CV-8i RAID controller. These products are designed to deliver high performance, scalability, and reliability, making them ideal for mission-critical applications across various industries.

The UCSSP6C220E is an essential component for the Cisco Unified Computing System (UCS) environment. It is designed for exceptional performance in virtualization and cloud computing environments. Key features include support for Intel Xeon Scalable processors, allowing for improved processing power and efficiency. Additionally, the server supports numerous memory configurations, with support for up to 3TB of RAM using 24 DIMM slots. With its innovative design, the UCSSP6C220E provides efficient cooling and power management, ensuring optimal performance under heavy workloads.

The UCUCSEZC220M3S model further enhances the capabilities of Cisco UCS with its flexible storage options and advanced management features. It supports multiple networking technologies, enabling seamless integration into existing IT infrastructures. The server's scalability is a significant benefit, accommodating a wide variety of workloads from virtualization to high-performance computing.

The UCS C220 series is a versatile platform known for its balance of performance, storage, and density. It is ideal for running more applications while minimizing data center space. The C220 server can support both SAS and SATA drives, enabling businesses to choose the right storage solution for their specific needs.

The 9266CV-8i RAID controller is a robust solution designed to enhance data protection and performance. It supports RAID levels 0, 1, 5, 6, 10, 50, and 60, providing multiple options for balancing performance and redundancy. With 1GB of integrated cache memory, it helps accelerate data access, while its eight internal ports ensure high connectivity and flexibility for storage expansions.

Coupled with the UCSRAID9266CV, this controller simplifies storage management with advanced features such as online capacity expansion and dynamic RAID migration. Together, these technologies help organizations optimize their data centers while ensuring high availability and reliability, making Cisco Systems’ offerings a cornerstone for enterprise IT infrastructures.