Chapter 3 Maintaining the Server

Installing or Replacing Server Components

Replacing a Drive Backplane

Note The Small Form Factor (eight-drive) and Large Form Factor (four-drive) backplanes and their corresponding chassis drive bays are factory-configurable options. When replacing a backplane, you must replace it with the same version of the backplane.

To install or replace a drive backplane, follow these steps:

Step 1 Remove the drive backplane that you are replacing. See Figure 3-9:

a.Power off the server as described in the “Shutting Down and Powering Off the Server” section on page 3-7.

b.Slide the server out the front of the rack far enough so that you can remove the top cover. You might have to detach cables from the rear panel to provide clearance.

Caution If you cannot safely view and access the component, remove the server from the rack.

c.Remove the top cover as described in “Removing and Replacing the Server Top Cover” section on page 3-8.

d.Remove all drives from the server.

Tip Label the drives as you remove them to aid replacement.

e.Disconnect all cables from the backplane.

f.Loosen the two captive thumbscrews that secure the backplane to the chassis floor (see Figure 3-9).

g.Loosen the single captive thumbscrew that secures the backplane to the operations panel assembly (see Figure 3-9).

The operations panel assembly plugs into a socket on the front side of the backplane.

h.Push the operations panel assembly forward and out the front of the chassis about one inch to disengage it from the backplane. Push on the small metal handle that is engraved with an arrow (see Figure 3-9).

i.Lift straight up on the backplane to disengage it from the three supporting metal hooks on the chassis.

Step 2 Install a new drive backplane:

a.Carefully set the backplane in place so that the three slotted holes in its circuit board fit over the three supporting hooks on the chassis (see Figure 3-9).

b.Push the operations panel assembly inward until it is fully engaged with the socket on the backplane.

c.Tighten the single captive thumbscrew that secures the backplane to the operations panel assembly.

d.Tighten the two captive thumbscrews that secure the backplane to the chassis floor.

e.Reconnect all cables to the backplane.

f.Replace all drives to the server.

g.Replace the top cover.

h.Replace the server in the rack, replace cables, and then power on the server by pressing the Power button.

 

Cisco UCS C220 Server Installation and Service Guide

3-14

OL-25760-01

Page 50
Image 50
Cisco Systems UCSSP6C220E, UCUCSEZC220M3S, UCSRAID9266CV, 9266CV-8i manual Replacing a Drive Backplane

UCSRAID9266CV, C220, 9266CV-8i, UCSSP6C220E, UCUCSEZC220M3S specifications

Cisco Systems offers a range of powerful solutions for data center and enterprise infrastructures, among which are the UCSSP6C220E and UCUCSEZC220M3S, as well as the UCS C220 servers and the 9266CV-8i RAID controller. These products are designed to deliver high performance, scalability, and reliability, making them ideal for mission-critical applications across various industries.

The UCSSP6C220E is an essential component for the Cisco Unified Computing System (UCS) environment. It is designed for exceptional performance in virtualization and cloud computing environments. Key features include support for Intel Xeon Scalable processors, allowing for improved processing power and efficiency. Additionally, the server supports numerous memory configurations, with support for up to 3TB of RAM using 24 DIMM slots. With its innovative design, the UCSSP6C220E provides efficient cooling and power management, ensuring optimal performance under heavy workloads.

The UCUCSEZC220M3S model further enhances the capabilities of Cisco UCS with its flexible storage options and advanced management features. It supports multiple networking technologies, enabling seamless integration into existing IT infrastructures. The server's scalability is a significant benefit, accommodating a wide variety of workloads from virtualization to high-performance computing.

The UCS C220 series is a versatile platform known for its balance of performance, storage, and density. It is ideal for running more applications while minimizing data center space. The C220 server can support both SAS and SATA drives, enabling businesses to choose the right storage solution for their specific needs.

The 9266CV-8i RAID controller is a robust solution designed to enhance data protection and performance. It supports RAID levels 0, 1, 5, 6, 10, 50, and 60, providing multiple options for balancing performance and redundancy. With 1GB of integrated cache memory, it helps accelerate data access, while its eight internal ports ensure high connectivity and flexibility for storage expansions.

Coupled with the UCSRAID9266CV, this controller simplifies storage management with advanced features such as online capacity expansion and dynamic RAID migration. Together, these technologies help organizations optimize their data centers while ensuring high availability and reliability, making Cisco Systems’ offerings a cornerstone for enterprise IT infrastructures.