Cisco Systems UCSSP6C220E manual Mixing Drive Types in RAID Groups, Mix of Drive Types, Allowed?

Models: UCSRAID9266CV C220 9266CV-8i UCSSP6C220E UCUCSEZC220M3S

1 124
Download 124 pages 40.24 Kb
Page 101
Image 101
Mixing Drive Types in RAID Groups

Appendix C RAID Controller Considerations

Mixing Drive Types in RAID Groups

Table C-2

Cisco UCS C220 M3 Large Form Factor Drives RAID Options

 

 

 

 

Maximum

BBU or

 

 

Controller

 

Style

Drives

SCPM1

RAID Levels

Required Cables

Embedded MegaRAID2

Onboard

4 SATA or

No

0, 1, 54, 10

4 drives:

 

 

 

4 SAS3

 

 

1 mini-SAS (UCSC-CABLE3)

 

 

 

internal

 

 

 

 

 

 

 

 

 

Cisco UCS RAID SAS

Mezzanine

4 internal

No

0, 1, 1E, 10

4 drives:

2008M-8i:

 

 

 

 

 

1 mini-SAS (UCSC-CABLE3)

PID UCSC-RAID-MZ-C220

 

 

 

 

 

 

 

 

 

 

 

Cisco UCS RAID SAS

Mezzanine

4 internal

No

0, 1, 1E, 5, 10,

4 drives:

2008M-8i:

 

 

 

 

50

1 mini-SAS (UCSC-CABLE3)

PID UCSC-RAID-11-C220

 

 

 

 

 

(Includes RAID 5 & 50)

 

 

 

 

 

 

 

 

 

 

 

LSI MegaRAID SAS 9266-8i

PCIe

4 internal

BBU

0, 1, 5, 6, 10,

4 drives:

The cache memory of this

 

 

 

50, 60

1 mini-SAS (UCSC-CABLE3)

controller is ECC-protected.

 

 

 

 

 

 

 

 

 

 

 

LSI MegaRAID SAS

PCIe

4 internal

SCPM

0, 1, 5, 6, 10,

4 drives:

9266CV-8i

 

 

 

 

50, 60

1 mini-SAS (UCSC-CABLE3)

The cache memory of this

 

 

 

 

 

controller is ECC-protected.

 

 

 

 

 

 

 

 

 

 

 

LSI MegaRAID SAS

PCIe

8 external

SCPM

0, 1, 5, 6, 10,

Not sold by Cisco

9285CV-8e

 

 

 

 

50, 60

 

 

 

 

 

 

 

 

1.BBU = battery backup unit. SCPM = SuperCap power module.

2.Migrations from a RAID card to the embedded controller are not supported after-factory. See RAID Controller Migration, page C-6.

3.Support for four SAS drives requires an optional SCU upgrade ROM module on the motherboard.

4.Support for RAID 5 requires an optional RAID 5 software key module on the motherboard.

Mixing Drive Types in RAID Groups

Following are the rules for mixing hard disk drive (HDD) and solid state drive (SSD) types in a RAID group with the supported controllers.

Table C-3 Drive Type Mixing in RAID Groups

Mix of Drive Types

 

in RAID Group

Allowed?

 

 

SAS HDD + SATA HDD

Yes

 

 

SAS SSD + SATA SSD

Yes

 

 

HDD + SSD

No

 

 

Cisco UCS C220 Server Installation and Service Guide

 

OL-25760-01

C-3

 

Page 101
Image 101
Cisco Systems UCSSP6C220E, UCUCSEZC220M3S, UCSRAID9266CV Mixing Drive Types in RAID Groups, Mix of Drive Types, Allowed?