Covers Server Generation M3 April 12
Cisco Systems, Inc 170 West Tasman Drive San Jose, CA
800 553-NETS Fax 408
Cisco UCS C220 Server Installation and Service Guide
Reorient or relocate the receiving antenna
Initial Server Setup
NIC Modes and NIC Redundancy Settings
Using the Clear CMOS Header J37
Installing the Server
DIMM Replacement Procedure
Server Configuration Utility
PCIe Slots
Maintaining the Server
Launching the LSI Embedded RAID Configuration Utility C-11
Installing a Trusted Platform Module
Server Specifications
Physical Specifications
Installation for Cisco UCS Integration D-1
For More Information C-23
Contents
Cisco UCS C220 Server Installation and Service Guide
Installing the Server
Server Specifications
Power Cord
Specifications
Audience
Documentation Feedback
Conventions
viii
Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA
Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo
Preface Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
xiii
Obtaining Documentation and Submitting a Service Request
Preface Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
External Features Overview
External Features Overview, page Summary of Server Features, page
Overview
C H A P T E R
HDD1
HDD2
HDD3
HDD4
PCIe1
Summary of Server Features
PCIe2
See Replacing a PCIe Card, page 3-33 for slot specifications
page
Considerations, page C-1
Power
Installing the Server
Preparing for Server Installation, page
Installing the Server In a Rack, page Initial Server Setup, page
System BIOS and CIMC Firmware, page
Unpacking and Inspecting the Server
Preparing for Server Installation
Installation Guidelines
Installation Guidelines, page Rack Requirements, page
Equipment Requirements, page Slide Rail Adjustment Range, page
Equipment Requirements
Slide Rail Adjustment Range
Rack Requirements
Installing the Server In a Rack
Figure 2-3 Attaching a Slide-Rail Assembly
Step 5 Continue with the “Initial Server Setup” section on page
Flange on rear of outer left slide rail
Initial Server Setup
Connecting and Powering On the Server Standalone Mode
Connecting and Powering On the Server Standalone Mode, page
NIC Modes and NIC Redundancy Settings, page
Active-active-All Ethernet ports are utilized simultaneously
2-10
Step 4 Connect to the CIMC for server management. Connect Ethernet cables from your LAN to the server, using the ports that you selected by your NIC Mode setting in Step 3. The Active-active and Active-passive NIC redundancy settings require you to connect to two ports
NIC Modes and NIC Redundancy Settings
2-11
System BIOS and CIMC Firmware
Updating the BIOS and CIMC Firmware
Accessing the System BIOS, page
See the Cisco UCS C-Series Rack-Mount Server BIOS Upgrade Guide
Accessing the System BIOS
2-13
Service Headers and Jumpers
Using the BIOS Recovery Header J41, page
Using the Clear CMOS Header J37, page
Header Locations on the Motherboard
2-15
Using the BIOS Recovery Header J41
Procedure 1 Reboot With recovery.cap File
Procedure 2 Use Recovery Jumper and recovery.cap File
2-16
Using the Clear CMOS Header J37
2-17
2-18
Chapter 2 Installing the Server Service Headers and Jumpers
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Server Configuration Utility
Preparing for Server Component Installation, page
Installing or Replacing Server Components, page
Maintaining the Server
Internal Diagnostic LEDs, page
Power button/Power status LED
Off-There is no AC power to the server
Status LEDs and Buttons
Front Panel LEDs, Definitions of States continued
LED Name
State
Rear Panel LEDs, Definitions of States
Rear Panel LEDs and Buttons
Figure 3-2 Rear Panel LEDs and Buttons
Rear Panel LEDs, Definitions of States continued
LED Name
State
Internal Diagnostic LEDs
Internal diagnostic LEDs all
Off-Component is functioning normally
Amber-Component has failed
Preparing for Server Component Installation
Shutting Down and Powering Off the Server
Shutting Down and Powering Off the Server, page
Required Equipment
Removing and Replacing the Server Top Cover
Front cover panel
Rubber finger pads two
Release button
Replaceable Component Locations
Figure 3-5 Replaceable Component Locations
3-10
Serial Number Location
Color-Coded Touch Points
Installing or Replacing Server Components
Replacing the Motherboard RTC Battery, page
Installing a Trusted Platform Module, page
Replacing a SCU Upgrade ROM Module, page
Drive Population Guidelines, page Drive Replacement Procedure, page
Replacing Hard Drives or Solid State Drives
Drive Population Guidelines
3-12
Drive Replacement Procedure
3-13
HDD1
HDD2
Replacing a Drive Backplane
3-14
3-15
Figure 3-9 Replacing the Drive Backplane
FAN1
FAN2
Figure 3-10 Fan Module Numbering
Replacing Fan Modules
3-16
3-17
Installing or Replacing Server Components
Cisco UCS C220 Server Installation and Service Guide
Chapter 3 Maintaining the Server
DIMM Replacement Procedure, page
Replacing DIMMs
Memory Performance Guidelines and Population Rules
DIMM Slot Numbering
DIMM Population Rules
3-19
Front of Server
CPU1 CPU2
Enabling Low-Voltage DIMM Operation Power Saving Mode
3-20
DIMM Parameter Mixed
Mix Across Single Channel?
DIMM Sparing and Rank Sparing
Memory Mirroring
3-21
Number of DIMMs
DIMM Replacement Procedure
Identifying a Faulty DIMM
Identifying a Faulty DIMM, page Replacing DIMMs, page
Replacing DIMMs
Step
Replacing CPUs and Heatsinks
3-23
Figure 3-14 Protective Cap Removal Tool
3-24
Figure 3-13 CPU Heatsink and Socket
3-25
Arrow on tool
3-26
Figure 3-16 CPU and Pick-and-Place Tool on Pedestal
3-27
f. Replace the top cover
Replacing the Motherboard RTC Battery
3-28
3-29
RTC battery holder on motherboard
Replacing a Mezzanine Card
3-30
Figure 3-19 Replacing the Mezzanine Card
PCIe1
PCIe2
Replacing a PCIe Riser
PCIe
3-31
PCIe
3-32
Installing or Replacing Server Components
Cisco UCS C220 Server Installation and Service Guide
Chapter 3 Maintaining the Server
Installing Multiple PCIe Cards and Resolving Limited Resources, page
Replacing a PCIe Card
PCIe Slots
PCIe Slots, page Replacing a PCIe Card, page
Replacing a PCIe Card
3-34
Special Considerations for Cisco UCS Virtual Interface Cards
RAID Controller Card Cable Routing
3-35
Cisco UCS C220 Requirements for Virtual Interface Cards
Installing Multiple PCIe Cards and Resolving Limited Resources
See also Factory-Default Option ROM Settings, page C-4
Resolving Insufficient Memory Space to Execute Option ROMs
Resolving Insufficient Memory Space to Execute Option ROMs, page
Resolving Insufficient 16-Bit I/O Space
3-37
Overview of the Pre-Installed Cisco Flexible Flash Card
Overview of the Pre-Installed Cisco Flexible Flash Card, page
Booting a Cisco Flexible Flash Virtual Drive, page
Cisco Flexible Flash Card Replacement Procedure, page
Booting a Cisco Flexible Flash Virtual Drive
Booting the Cisco SCU and Cisco HUU Software VDs
Booting the Cisco SCU and Cisco HUU Software VDs, page
Booting the Hypervisor VD, page
Cisco Flexible Flash Card Replacement Procedure
Booting the Hypervisor VD
Monitoring and Managing a Cisco Flexible Flash Card
3-40
3-41
Step 2 Install a Cisco Flexible Flash card
Replacing the LSI RAID Battery Backup Unit or SuperCap Power Module
3-42
3-43
Installing or Replacing Server Components
Cisco UCS C220 Server Installation and Service Guide
Chapter 3 Maintaining the Server
Installing a Trusted Platform Module
3-44
3-45
Figure 3-25 TPM Socket Location on Motherboard
CPU1
PSU2
d. Set Intel R VT and Intel R VT-d to Enabled
3-46
b. Set TXT Support to Enabled
Figure 3-26 SCU Upgrade ROM Module Retention Feature
Replacing a SCU Upgrade ROM Module
3-47
Figure 3-27 Software RAID Key Module Retention Feature
Replacing a Software RAID Key Module
3-48
Replacing Power Supplies
3-49
Enabling or Disabling the Internal USB Port
3-50
Server Specifications
Physical Specifications
Physical Specifications, page A-1
Environmental Specifications, page A-2 Power Specifications, page A-3
Environmental Specifications
Power Specifications
450W Power Supply
650W Power Supply
450W Power Supply, page A-3 650W Power Supply, page A-3
OL-25760-01
Appendix A Server Specifications Power Specifications
Cisco UCS C220 Server Installation and Service Guide
Power Cord Specifications
Supported Power Cords and Plugs
A P P E N D I X B
Figure B-1
Figure B-7
Figure B-8
Figure B-9
Figure B-10
AC Power Cord Illustrations
Connector
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Cisco UCS C220 Server Installation and Service Guide
M2511
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Cisco UCS C220 Server Installation and Service Guide
I/3G
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Connector
Cisco UCS C220 Server Installation and Service Guide
Plug
CAB-C13-C14-2M, Jumper Power Cord 2 m
CAB-C13-C14-AC, Jumper Power Cord 3 m
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Appendix B Power Cord Specifications Supported Power Cords and Plugs
Cisco UCS C220 Server Installation and Service Guide
Factory-Default Option ROM Settings, page C-4
RAID Backup Units, page C-5 RAID Controller Migration, page C-6
RAID Controller Considerations
A P P E N D I X C
Supported RAID Controllers and Required Cables
Mixing Drive Types in RAID Groups
Mix of Drive Types
in RAID Group
Allowed?
Factory-Default Option ROM Settings
Table C-5 Drive Type Mixing in RAID Groups
RAID Backup Units
Mixing Drive Types in RAID Groups
RAID Controller Migration
Starting RAID Controller
Migrate to HW RAID Allowed?
Migrate to SW RAID Allowed?
Enabling the Embedded RAID Controller in the BIOS, page C-10
Disabling the Embedded RAID Controller in the BIOS, page C-11
Launching the LSI Embedded RAID Configuration Utility, page C-11
Installing LSI MegaSR Drivers For Windows and Linux, page C-11
Notes on Supported Embedded MegaRAID Levels
Installing a SCU Upgrade ROM Module For Embedded RAID SAS Support
C-10
Installing a Software RAID Key Module for Embedded RAID 5 Support
Enabling the Embedded RAID Controller in the BIOS
Disabling the Embedded RAID Controller in the BIOS
Launching the LSI Embedded RAID Configuration Utility
Installing LSI MegaSR Drivers For Windows and Linux
Microsoft Windows Driver Installation, page C-12
Microsoft Windows Driver Installation
Windows Server 2008R2 Driver Installation
Windows Server 2008R2 Driver Installation, page C-12
Downloading the LSI MegaSR Drivers
Updating the Windows Driver
C-13
Linux Driver Installation
Preparing Physical Installation Diskettes For Linux
Preparing Physical Installation Diskettes For Linux, page C-14
Installing the Red Hat Linux Driver, page C-16
dd if=dud-driver version.img of=/dev/fd0
C-15
Preparing Installation Disks With a Linux Operating System
Installing the Red Hat Linux Driver
C-16
Installing the SUSE Linux Enterprise Server 11 Driver
C-17
C-18
Step 14 Press OK
RAID Controller Cabling
Cable Routing
Cable Routing, page C-19 Cisco UCS C220 Server Cabling, page C-20
C-19
Cisco UCS C220 Server Cabling
Backplane and Expander Options
SFF 8-Drive Backplane Cabling
Embedded RAID
C-21
Cisco UCS RAID SAS 2008M-8i Mezzanine Card
LSI MegaRAID SAS 9266-8i or 9266CV-8i PCIe Card
LFF 4-Drive Backplane Cabling
C-22
Embedded RAID
Cisco UCS RAID SAS 2008M-8i Mezzanine Card
Restoring RAID Configuration After Replacing a RAID Controller
For More Information
C-23
C-24
Cisco UCS C220 Server Installation and Service Guide
Appendix C RAID Controller Considerations For More Information
OL-25760-01
Installation for Cisco UCS Integration
A P P E N D I X D
OL-25760-01
Appendix D Installation for Cisco UCS Integration
Cisco UCS C220 Server Installation and Service Guide