Desa CGESS Grounding Instructions, Operating Instructions, Cleaning Maintenance, Bulb Replacement

Models: CGESS

1 8
Download 8 pages 1.52 Kb
Page 4
Image 4

GROUNDING

INSTRUCTIONS

This stove is for use on 120 volts. The cord has a plug as shown in Figure 2. An adapter is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.

You should heara small clicking sound indicat- ing the heater has started and heat will emit from the vents at the top of the unit from the front. To turn off heater, turn the dial counter clockwise past number 1 and turn the Heater Switch to OFFposition.To increase the desired temperature, turn the dial clockwise towards

Number 9.

Main Power

 

Flame Switch

 

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grounding Pin

Adapter

Figure 2 - Grounding Methods

OPERATING

INSTRUCTIONS

Once the unit has been properly connected to a ground electrical outlet, it is ready to operate. Note: Ensure the circuit breakers for power supply are turned on.

CONTROL PANEL OPERATION

Controls are located on the back of the unit near the top (see Figure 3).

1.Main ON/OFF power switch: This switch is located at the furthest right corner on the control panel when looking at the back of the unit. Turn the switch to ON and unit will be ready to operate. The "" indicates ON and "O" indicates OFF.

2.Flame ON/OFF Switch: This switch is located in the middle between the Main ON/OFF switch and the Heater ON/OFF switch on the control panel when looking at the back of the unit. Turn the switch to ON and the flame effect will turn on. The "" indicates ON and the "O" indicates OFF.

3.Heater ON/OFF Switch: This switch is located to the left of the Flame ON/OFF switch on the control panel. It has a symbol of the sun directly below it.

4.Thermostat Control Dial: This dial is located at the furthest left corner on the control panel. It has a symbol of a thermostat directly below it. Turn the dial clockwise past the number 8.

Built-In

Heater Switch

Thermostat

 

Figure 3 - Electric Stove Control Panel

CLEANING AND

MAINTENANCE

WARNING: Always discon- nect power and allow the heater to cool before performing any cleaning, maintenance or reloca- tion of this heater. Turn controls to OFF and remove plug from outlet or turn off circuit breaker to heater.

Turn off heater and circuit breaker to heater before performing any cleaning and/or maintenance. Al- low heater to cool completely.

BULB REPLACEMENT

WARNING: The halogen light bulbs in your unit can become extremely hot. Allow at least 10 minutes between turning off the heater and removing the light bulbs to avoid accidental burns.

There are a total of 4 ( halogen light bulbs (type GX6.35 rated 120 volts, 35 watts) in your unit.

1 bulbs provide illumination for the ember bed beneath the log set

1 bulbs provide illumination for the flame generation assembly

2 bulbs for replacement

4

www.desatech.com

117889-01B

Page 4
Image 4
Desa CGESS Grounding Instructions, Operating Instructions, Cleaning Maintenance, Control Panel Operation, Bulb Replacement