Desa CGN10R installation manual Connecting, To Gas Supply, Checking Gas Connections, Continued

Models: CGN10R

1 28
Download 28 pages 1.88 Kb
Page 14
Image 14
CONNECTING

CONNECTING

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping

TO GAS SUPPLY

Continued

and/or fittings.

3/8" NPT Pipe Nipple

Ground Joint Union Manual TO GAS SUPPLYCHECKING GAS CONNECTIONS

Pressure Regulator

Heater

Cabinet

Shutoff Valve *

Tee Joint

CHECKING GAS CONNECTIONS

14

 

Reducer

Test

From Gas Meter

Bushing to

Gauge

1/8" NPT

Connection *

(4" W.C. to

 

 

 

10.5" W.C. Pressure)

1/8" NPT

 

 

Plug Tap

 

3" Minimum

Tee

 

Joint

Sediment

 

Pipe

 

Trap

 

Nipple

 

 

Cap

Figure 12 - Gas Connection

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessory, page 26.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM WARNING

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

Manual background WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.