Desa CGN10R Fresh Air For Combustion And Ventilation, Continued, Ventilated Outlet Attic Air

Models: CGN10R

1 28
Download 28 pages 1.88 Kb
Page 8
Image 8
Ventilated

FRESH AIR FOR COMBUSTION AND VENTILATION

Continued

8

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

101867

Page 8
Image 8
Desa CGN10R Fresh Air For Combustion And Ventilation, Continued, Ventilated Outlet Attic Air, To Attic, Inlet Air