INSTALLATION

OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE WARNING: A qualified ser- vice person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below:

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

test gauge connection *

sediment trap

tee joint

pipe wrench

*An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connec- tion. Purchase the optional CSA/AGA de- sign-certified equipment shutoff valve from your dealer. See Accessory, page 16.

LOCATING HEATER

This heater is designed to be mounted on a wall.

INSTALLATION ITEMS WARNING: Maintain the mini- mum clearances shown in Figure

4.If you can, provide greater clear- ances from floor, ceiling, and join- ing wall.

LOCATING HEATER WARNING: Never install the heater

in a bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

THERMOSTAT SENSING BULB CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

INSTALLING HEATER TO WALL CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving ve- hicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

CEILING

36"

Minimum

Manual background 6" Minimum

From Manual backgroundManual backgroundManual background Sides Of

Heater

Right

LeftSide

Side

Manual background Minimum to Top 3"Surface of

Carpeting, Tile or

FLOOR Other Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

THERMOSTAT SENSING BULB

The thermostat sensing bulb is located in- side the heater. Do not move this bulb dur- ing installation or operation of the heater.

INSTALLING HEATER TO WALL

Marking Screw Locations

1.Determine where you will locate heater.

Manual backgroundWARNING: Maintain minimum clearances shown in Figure 5. If you can, provide greater clear- ances from floor and joining wall.

2.Mark two mounting screw loca- tions on wall (see Figure 5).

8 7/8"Manual backgroundManual background7 3/4"Manual backgroundManual background

Minimum To

Maintain 6"

Clearance

From Wall

 

Mounting

20 1/4"

WALL

Screw

Minimum To

Locations

Maintain 3"

 

Clearance

JOINING

 

From Floor

 

 

FLOOR

Figure 5 - Mounting Screw Locations

Continued