LIGHTING
C-clockwise

OWNER’S MANUAL

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety informa- tion, page 10.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clock-

wise ClockwiseTO TURN OFF GAS TO to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, includ- ing near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation on page 10. If you don’t smell gas, go to the next step.

5.Turn control knob counterclock-

wise THERMOSTAT to the PILOT posi- tion. Press in control knob for five

(5) seconds (see Figure 15).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is at- tached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ig- nitor button until pilot lights.

Note: If pilot does not stay lit, re- fer to Troubleshooting, pages 13 through 15. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pi- lot with match, see Manual Light- ing Procedure, column 3.

7.Keep control knob pressed in for 30 seconds after lighting pilot. Af- ter 30 seconds, release control knob.

If control knob does not pop up when released, contact a quali- fied service person or gas sup- plier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

MANUAL LIGHTINGC-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

Manual background CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Control

Button Knob

PILOT

LO

OFF

 

HI

 

IGNITOR

Figure 15 - Control Knob In The OFF Position

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 16 - Pilot

TO TURN OFF GAS TO

APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise ClockwiseManual background to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise ClockwiseManual background to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 8).

2.Follow steps 1 through 5 under Light- ing Instructions, column 1.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions, column 2.

5.Replace front panel.