OBSERVED

 

POSSIBLE

 

 

 

 

PROBLEM

 

CAUSE

 

 

REMEDY

 

 

 

 

 

 

 

 

Burner(s) does

not

1. Burner

orifice(s)

is

1.

Clean burner orifice(s)

light after ODS/pilot is

 

clogged

 

 

 

(see CLEANING AND

lit

 

 

 

 

 

 

MAINTENANCE, page

 

 

 

 

 

 

 

17) or replace burner

 

 

 

 

 

 

 

orifice(s)

 

 

2.

Burner

orifice(s)

di-

2.

Replace burner orifice(s)

 

 

 

ameter is too small

 

 

 

 

 

 

3.

Inlet gas pressure is too

3.

Contact local natural gas

 

 

 

low

 

 

 

company

 

 

 

 

 

 

Delayed ignition

of

1.

Manifold pressure is too

1.

Contact local natural gas

burner(s)

 

 

low

 

 

 

company

 

 

2.

Burner

orifice(s)

is

2.

Clean burner orifice(s)

 

 

 

clogged

 

 

 

(see CLEANING AND

 

 

 

 

 

 

 

MAINTENANCE, page

 

 

 

 

 

 

 

17) or replace burner

 

 

 

 

 

 

 

orifice(s)

 

 

 

 

 

 

 

 

 

Burner backfiring

 

1.

Burner

orifice(s)

is

1.

Clean burner orifice(s)

during combustion

 

clogged or damaged

 

 

(see CLEANING AND

 

 

 

 

 

 

 

MAINTENANCE, page

 

 

 

 

 

 

 

17) or replace burner

 

 

 

 

 

 

 

orifice(s)

 

 

2.

Burner damaged

 

2.

Replace burner

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

 

 

 

Burner plaque(s) does

1.

Plaque damaged

not glow

2.

Inlet gas pressure is too

 

 

low

 

3.

Control knob set be-

 

 

tween locked positions

1.Replace burner

2.Contact local natural gas company

3.Turn control knob until it locks at desired setting

Slight smoke or odor

1. Residues from manu-

1. Problem will stop after a

during initial opera-

facturing processes

few hours of operation

tion

 

 

 

 

 

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or contracting while cooling

1.This is common with most heaters. If noise is excessive, contact quali- fied service person