REMEDY

 

 

 

Heater produces un-

1.

Heater burning vapors

wanted odors

 

from paint, hair spray,

 

 

glues, etc.

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Ventilate room. Stop us- ing odor-causing prod- ucts while heater is run- ning

2.Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 10)

Heater shuts off in use

1.

Not enough fresh air is

(ODS operates)

 

available

 

2.

Low line pressure

 

3.

ODS/pilot is partially

 

 

clogged

1.Open window and/or door for ventilation

2.Contact local natural gas company

3.Clean ODS/pilot (see

CLEANING AND MAINTENANCE, page 17)

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in OFF

 

ing statement at

 

leaks (see CHECKING

position

 

top of page

 

GAS CONNECTIONS,

 

 

 

 

page 10)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during com-

1.

Foreign matter between

bustion

 

control valve and

 

 

burner

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Take apart gas tubing and remove foreign mat- ter

2.Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 10)