Desa RP30B, CGP18B installation manual From

Models: CGP18B RP30B

1 32
Download 32 pages 12.64 Kb
Page 23
Image 23

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Burner does not light

2.

Burner orifice diameter

2.

Replace burner orifice

after ODS/pilot is lit

 

is too small

 

 

(continued from

3.

Inlet gas pressure is

3.

Contact local propane

page 22)

 

too low

 

gas company

Delayed ignition of

1.

Manifold pressure is

burner

 

too low

 

2.

Burner orifice is

 

 

clogged

1.Contact local propane gas company

2.Clean burner (see Cleaning and Mainte- nance, page 21) or replace burner orifice

Burner backfiring

1.

Burner orifice is

1.

Clean burner (see

during combustion

 

clogged or damaged

 

Cleaning and Mainte-

 

 

 

 

nance, page 21) or

 

 

 

 

replace burner orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Yellow flame during

1. Not enough air

burner combustion

 

2. Gas regulator defective

1.Check burner for dirt and debris. If found, clean burner (see Cleaning and Mainte- nance, page 21)

2.Replace gas regulator

Slight smoke or odor

1. Residues from manu-

1. Problem will stop after a

during initial opera-

facturing processes

few hours of operation

tion

 

 

 

 

 

Heater produces a

1.

Turning control knob

whistling noise when

 

to HIGH position

burner is lit

 

when burner is cold

 

2.

Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1.Turn control knob to LOW position and let warm up for a minute

2.Operate burner until air is removed from line. Have gas line checked by local propane gas company

3.Observe minimum installation clearances (see Figure 4, page 10)

4.Clean burner (see Cleaning and Mainte- nance, page 21) or replace burner orifice

Continued

100098

23

Page 23
Image 23
Desa RP30B, CGP18B installation manual From