Desa RP30B, CGP18B installation manual Operating, Inspecting, Burner, Pilot Flame Pattern

Models: CGP18B RP30B

1 32
Download 32 pages 12.64 Kb
Page 19
Image 19

OPERATING

 

 

TO TURN OFF GAS TO APPLIANCE

 

HEATER

 

 

 

Shutting Off Heater

Continued

1. Turn control knob clockwise Clockwise to the PILOT position.

 

2.

Press in control knob and turn clockwise Clockwise to the OFF position.

 

3.

Turn off all electric power to the appliance if service is to be performed.

 

Shutting Off Burner Only (pilot stays lit)

 

1.

Turn control knob clockwise Clockwise to the PILOT position.

 

 

 

MANUAL LIGHTING PROCEDURE

 

 

 

 

 

 

 

 

 

 

 

1.

Remove front panel (see Figure 5, page 11).

 

2.

Follow steps 1 through 5 under Lighting Instructions, pages 17 and 18.

 

3.

With control knob pressed in, strike match. Hold match to pilot until pilot

 

 

lights.

 

4.

Keep control knob pressed in for 30 seconds after lighting pilot. After 30

 

 

seconds, release control knob.

INSPECTING

5.

Replace front panel.

Check pilot flame pattern and burner flame pattern often.

 

BURNER

PILOT FLAME PATTERN

 

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot

 

flame pattern. The incorrect pilot flame is not touching the thermocouple. This will

 

cause the thermocouple to cool. When the thermocouple cools, the heater will shut

 

down.

 

 

 

Pilot Burner

 

 

Thermocouple

GOOD PILOT/LP

GRH/OV 007

Figure 18 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

BAD PILOT/LP

GRH/OV 008

Figure 19 - Incorrect Pilot Flame Pattern

Continued 19

100098

Page 19
Image 19
Desa RP30B, CGP18B installation manual Operating, Inspecting, Burner, Pilot Flame Pattern