Desa CGS2718P Variable Control Operation, To Turn Off Gas To Appliance, Operating Heater

Models: CGS2718P

1 32
Download 32 pages 45.1 Kb
Page 21
Image 21
VARIABLE CONTROL OPERATION
C-clockwise

OPERATING HEATER

Continued

5. Slightly depress and turn control knob counterclockwise

C-clockwise

to the PILOT

 

position. Press in control knob for five (5) seconds (see Page 20).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 22.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

 

Ignitor

Pilot Burner

Thermocouple

Electrode

 

 

 

Figure 21 - Pilot

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8. Slightly depress and turn control knob counterclockwise TO TURN OFF GAS TO APPLIANCE to desired heating level. The burner should light. Set control knob to any heat level between HI and LO.

Shutting Off Heater WARNING

Do not operate heater between PILOT and HIGH positions.

VARIABLE CONTROL OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

Shutting Off Burners Only (pilot stays lit) CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

 

 

 

 

1.

Press in and turn control knob clockwise

Clockwise

to the HIGH position.

2.

Turn control knob clockwise

Clockwise

to the pilot position.

3.

Press in control knob and turn clockwise

Clockwise

to the OFF position.

Shutting Off Burners Only (pilot stays lit)

 

 

1.

Turn control knob clockwise

Clockwise

to the HIGH position.

2.

Press in and turn control knob clockwise

Clockwise

to the pilot position.

Continued 21

102989

Page 21
Image 21
Desa CGS2718P Variable Control Operation, To Turn Off Gas To Appliance, Operating Heater, Continued, Shutting Off Heater