Desa CGS2718P Technical Service, Service Hints, Specifications, When gas pressure is too low

Models: CGS2718P

1 32
Download 32 pages 45.1 Kb
Page 27
Image 27
TECHNICAL

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

 

18" Model

24" Model

Btu (Variable)

16,000/27,000

16,000/31,500

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Manifold Pressure

8.0" W.C.

8.0" W.C.

Inlet Gas

 

 

Pressure (in. of water)

 

 

Maximum

14"

14"

Minimum*

11"

11"

Shipping Weight

27 lbs.

29 lbs.

* For the purpose of input adjustment

When gas pressure is too low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

27

102989

Page 27
Image 27
Desa CGS2718P Technical Service, Service Hints, Specifications, When gas pressure is too low, When gas quality is bad