Setup

Connect FTS and Heated Dual Whip Hose

NOTICE

To prevent damage to probe, do not kink or excessively bend hose. Do not coil hose tighter than the minimum bend radius of 3 ft (0.9 m). Do not subject hose to excessive weight, impact, or other abuse.

1.Carefully extend FTS probe (H) into the hose section from the proportioner. Do not bend or kink probe. Insert in component A (ISO) side of main hose for foam or poly- urea systems.

2.Connect FTS (J) to whip hose (W).

3.Connect whip hose ground wire (K) to ground screw on underside of FTS.

4. Connect fluid hoses to FTS (J).

To use 1/2 in. (13 mm) ID fluid hoses, remove the adapters from the propor- tioner fluid manifold and install them in

the FTS swivel inlets.

5.Connect electrical connectors (D).

6.Connect air hose (C) to whip air hose (L).

7.Connect hose assembly cable (F) to FTS cable (R). Slide insulator sleeves (S) over connection. Leave slack (G) in cables as stress relief, to prevent cable failure.

8.Check hoses for leaks (see your Heated Hose manual).

 

D

B

 

To Gun

 

K

 

 

 

 

 

J

 

 

 

 

 

 

 

 

 

To Proportioner

S

 

 

 

 

 

R

 

 

 

 

 

F

 

 

 

 

S

 

 

A

W

 

 

 

G

 

 

 

 

 

 

 

 

 

B A

H

L

C

TI9581C

FIG. 4: Connect FTS and Heated Dual Whip Hose

18

311511G

Page 18
Image 18
Graco 311511G important safety instructions Connect FTS and Heated Dual Whip Hose