Graco 311511G important safety instructions Power Jumper Location, Terminal Blocks

Models: 311511G

1 36
Download 36 pages 59.71 Kb
Page 16
Image 16

Setup

Step Two - Reposition Power Jumpers

Find location of Power Jumpers.

Power Jumper

Location

ti8609a

For 230V, 1 Phase and 230V, 3 Phase Installations, change jumper positions as shown below. Machine is shipped with jumpers in the fail-safe 380 3Ø position.

1.Remove upper rear control cover screws and cover.

2.Move one red jumper from the storage positions to the positions shown for your power.

A flat-blade screwdriver can be used under the ridge on the side of the jumper to remove them.

Push the jumper firmly into the new position.

3.Replace rear cover and two screws.

Step Two

TB2

Terminal Blocks

Position red jumpers (under back cover on opposite side)

, , , .

6 ’679%

(as shipped)

, , , .

6 ’6$ELTA

, , , .

6 ’

ti8610a

16

311511G

Page 16
Image 16
Graco 311511G important safety instructions Power Jumper Location, Terminal Blocks