Graco 311511G important safety instructions Circulation Through Gun Manifold, Ckn

Models: 311511G

1 36
Download 36 pages 59.71 Kb
Page 32
Image 32

Fluid Circulation

Circulation Through Gun Manifold

Read Warnings; see page 4. Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.

Circulating fluid through the gun manifold allows rapid preheating of hose.

1.Install gun fluid manifold (FM) on Part 246362 accessory circulation kit (CK).

FM

CKN

ti2767a

2.Connect high pressure circulation lines (N) to circulation manifold (CK). Route circulation lines back to respective component A or B supply drum. Use hoses rated at the maximum working pressure of this equipment.

3.Follow Load Fluid with Feed Pumps procedure; see page 21.

4.Turn Main Power Disconnect Switch (R) ON.

5.Open air inlet ball valve.

6.Set temperature targets; see page 22. Turn on heater.

Do not turn on hose heat unless hoses are already loaded with fluid.

7.Set both Air Regulator pressures to start at 15 psi (1.0 bar).

8.Turn PARK/RUN switch to RUN.

9.Turn Pump Mode Function switch to START.

10.Recirculate until desired temperature reaches set point.

11.Turn Pump Mode Function switch to OFF.

12.Close gun fluid manifold valves.

13.Reconnect gun to fluid manifold and air hose.

For additional recirculation information, refer to manual 309818.