Technical Data
Technical Data
Category | Data |
Maximum Fluid Working Pressure | 2000 psi (1.4 MPa, 140 bar) |
|
|
Maximum Air Working Pressure | 120 psi (0.84 MPa, 8.4 bar) |
|
|
Machine Maximum Power with hose | 9000 Watts |
|
|
Voltage Requirement (50/60 Hz) | 230 V, 1 Phase |
(230 V Nominal: | 230 V, 3 Phase (Delta) |
(380 V Nominal: | 380 V, 3 Phase (WYE 220 V Neutral) |
|
|
Amperage Requirement (Full Load Peak)* | 40 amps @ 230 V, 1 Phase |
| 32 amps @ 230 V, 3 Phase |
| 18.5 amps @ 380 V, 3 Phase |
|
|
Maximum Heater Fluid Temperature | 190 °F (88 °C) |
|
|
Maximum Hose Fluid Temperature | 180 °F (82 °C) |
|
|
Maximum Ambient Temperature | 120 °F (49 °C) |
|
|
Maximum Output | 20 lb/min. (9.0 kg/min.) |
|
|
Output Per Cycle (A and B) | .028 gal/cycle (.105 ltr/cycle) |
|
|
Overpressure Relief Shutdown | 2250 psi (15.5 MPa, 155 bar) |
|
|
Over Temperature Shutdown (Primary Heater) | 230 °F (110 °C) |
|
|
Heater Power | 6000 Watts |
|
|
Hose Power | 2790 Watts |
|
|
Sound Pressure | 86.3 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm) |
|
|
Sound Power, per ISO | 91.6 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm) |
|
|
Viscosity Range | |
|
|
Maximum Fluid Inlet Pressure | 400 psi (2.7 MPa, 27 bar) |
|
|
Fluid Inlet/Strainer Filter | 20 mesh standard |
|
|
Air inlet Filter Mesh | 5 Micron |
|
|
Component B (Resin) Inlet | 3/4 npt(f) swivel |
|
|
Component A (Isocyanate) Inlet | 1/2 npt(f) swivel |
|
|
Recirculation/Block Hose Connections | Iso (A) side: #5 JIC (m); Resin (B) side: #6 JIC (m) |
|
|
Maximum Heated Hose Length*** | 210 ft of 3/8 ID |
|
|
Height | 39.5 in. (1003.3 cm) |
|
|
Width | 27.2 in. (690.9 cm) |
|
|
Depth | 25.0 in. (635 cm) |
|
|
Weight | 250 lb (117.6 kg) |
|
|
Wetted Parts | Carbon steel, stainless steel, chrome, aluminum, |
| Fluoroelastomer, PTFE, nylon |
|
|
Certification | CE ** |
|
|
*Full load amps with all devices operating at maximum capabilities with 210 ft (64.1 m) of hose.
**When a surge transient is applied to the power lines of the unit, heat to the hose may be interrupted and require the hose heat switch to be manually cycled.
***210 ft (64 m) of heated hose will produce the maximum allowable heat capacity. 310 ft (94 m) of heated hose may be used, but will have 25% less heat capacity.
34 | 311511G |