Technical Data

Technical Data

Category

Data

Maximum Fluid Working Pressure

2000 psi (1.4 MPa, 140 bar)

 

 

Maximum Air Working Pressure

120 psi (0.84 MPa, 8.4 bar)

 

 

Machine Maximum Power with hose

9000 Watts

 

 

Voltage Requirement (50/60 Hz)

230 V, 1 Phase

(230 V Nominal: 195-253 VAC)

230 V, 3 Phase (Delta)

(380 V Nominal: 338-457 VAC)

380 V, 3 Phase (WYE 220 V Neutral)

 

 

Amperage Requirement (Full Load Peak)*

40 amps @ 230 V, 1 Phase

 

32 amps @ 230 V, 3 Phase

 

18.5 amps @ 380 V, 3 Phase

 

 

Maximum Heater Fluid Temperature

190 °F (88 °C)

 

 

Maximum Hose Fluid Temperature

180 °F (82 °C)

 

 

Maximum Ambient Temperature

120 °F (49 °C)

 

 

Maximum Output

20 lb/min. (9.0 kg/min.)

 

 

Output Per Cycle (A and B)

.028 gal/cycle (.105 ltr/cycle)

 

 

Overpressure Relief Shutdown

2250 psi (15.5 MPa, 155 bar)

 

 

Over Temperature Shutdown (Primary Heater)

230 °F (110 °C)

 

 

Heater Power

6000 Watts

 

 

Hose Power

2790 Watts

 

 

Sound Pressure

86.3 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm)

 

 

Sound Power, per ISO 9614-2

91.6 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm)

 

 

Viscosity Range

250-1500 centipoise

 

 

Maximum Fluid Inlet Pressure

400 psi (2.7 MPa, 27 bar)

 

 

Fluid Inlet/Strainer Filter

20 mesh standard

 

 

Air inlet Filter Mesh

5 Micron

 

 

Component B (Resin) Inlet

3/4 npt(f) swivel

 

 

Component A (Isocyanate) Inlet

1/2 npt(f) swivel

 

 

Recirculation/Block Hose Connections

Iso (A) side: #5 JIC (m); Resin (B) side: #6 JIC (m)

 

 

Maximum Heated Hose Length***

210 ft of 3/8 ID

 

 

Height

39.5 in. (1003.3 cm)

 

 

Width

27.2 in. (690.9 cm)

 

 

Depth

25.0 in. (635 cm)

 

 

Weight

250 lb (117.6 kg)

 

 

Wetted Parts

Carbon steel, stainless steel, chrome, aluminum,

 

Fluoroelastomer, PTFE, nylon

 

 

Certification

CE **

 

 

*Full load amps with all devices operating at maximum capabilities with 210 ft (64.1 m) of hose.

**When a surge transient is applied to the power lines of the unit, heat to the hose may be interrupted and require the hose heat switch to be manually cycled.

***210 ft (64 m) of heated hose will produce the maximum allowable heat capacity. 310 ft (94 m) of heated hose may be used, but will have 25% less heat capacity.