Setup

Setup

Locate Reactor A-20

Electrical Requirements

1.Locate Reactor A-20 on a level surface and bolt in place to the floor with 3/8 in. (10 mm) bolts.

Two bolts through the 2 in. (50 mm) deep caster bushings in the rear.

Two bolts through the 3-5/8 in. (168 mm) deep caster bushings in the front.

2.Do not expose Reactor A-20 to rain.

3.If you need to move the machine, add provided casters.

4.Lift with hoist only from bar spanning across top of cart.

Determine Power Source

Reactor A-20 can be wired to 3 types of power source:

230 Volt / 1 Phase

230 Volt / 3 Phase Delta

380 Volt / 3 Phase WYE

(220 Volts to Neutral)

Improper wiring may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician connect power and ground to main power switch terminals. Ensure your installation complies with all National, State, and Local safety and fire codes.

Also ensure that incoming power is disconnected and locked out at the source.

NOTICE

Ensure main power source meets all electrical requirements specified on nameplate of proportioning unit. Also ensure main power source has a dedicated fuse disconnect. Power cord is not supplied.